NOVA electronics Inc. MCX514 -
191
-
191
-
7.2.3
Acceleration Setting
Code
Command
Symbol
Data Range
Data Length
(byte)
02
h
Acceleration setting
AC
1
~
536,870,911
4
An acceleration setting value is a parameter that determines acceleration in linear acceleration/deceleration driving. The unit of the
setting value is pps/sec.
Acceleration = AC [pps/sec]
In linear acceleration/deceleration driving (WR3/D1=0) where acceleration and deceleration are symmetrical, this acceleration
setting value is also used at deceleration.
For S-curve acceleration/deceleration driving, set the maximum value of 536,870,911
(
1FFF FFFFh
)
to this parameter.
For Partial S-curve acceleration/deceleration driving, set the acceleration at linear acceleration part to this parameter.
In Partial S-curve acceleration/deceleration driving (WR3/D1=0) where acceleration and deceleration are symmetrical, this
acceleration setting value is also used at deceleration.
The value of current acceleration can be read by current acceleration / deceleration reading command (33h).
An acceleration setting value can be read by acceleration setting value reading command (43h).
7.2.4
Deceleration Setting
Code
Command
Symbol
Data Range
Data Length
(byte)
03
h
Deceleration setting
DC
1
~
536,870,911
4
This parameter is used to set a deceleration speed at deceleration in non-symmetrical linear acceleration/deceleration driving
(WR3/D1=1). The unit of the setting value is pps/sec.
Deceleration = DC [pps/sec]
In non-symmetrical S-curve acceleration/deceleration driving, set the maximum value of 536,870,911
(
1FFF FFFFh
)
to this
parameter.
In non-symmetrical Partial S-curve acceleration/deceleration driving, set the deceleration at linear deceleration part to this
parameter.