2.11
Input Signal Filter
This IC is equipped with an integral type filter in the input stage of each input signal. Figure 2.11-1 shows the filter configuration
of each input signal in X axis, and Y, Z and U axes have the same circuit as X axis. The time constant of a filter is determined by
the T oscillation circuit in the diagram. This IC has two time constants A and B, and it is determined by the kind of an input signal
which of the time constants A or B is used. Enable/disable of a filter and a time constant can be set by input signal filter mode
setting command (25h).
EMGN
XLMTP
XLMTM
XSTOP1
XINPOS
XALARM
T Oscillation Circuit
FLT
I
T
O
I
O
T
FLT
I
O
FLT
I
O
FLT
I
O
FLT
I
O
FLT
I
O
FLT
I
O
FLT
I
O
FLT
I
O
FLT
I
O
FLT
I
O
Time
Constant
T
T
T
T
T
T
T
T
T
T
T
o
In
te
rn
a
l
C
irc
u
it
Filter Time Constant B
Filter Time Constant A
T Oscillation Circuit
XSTOP0
XPIO0 - 3
XPIO
4
-
7
XSTOP2
XECA
FLT
I
O
T
XECB
D7
D6
D5
D4
H
L
D15
D14
D13
D12
D11
D10
D9
D8
D3
D2
D1
D0
FL00
FL01
FL02
FE7
FE4
FE5
FE6
FE3
FE1
FE2
FE0
FL13
FL03
FL10
FL11
FL12
Internal Register
Fig. 2.11-1 Concept of X axis Input Signal Filter Circuit