NOVA electronics Inc. MCX514 -
231
-
231
-
7.8.3
Deviation Counter Clear Output
Code
Command
72
h
Deviation counter clear output
This command outputs deviation counter clear pulses from the nDCC output pin.
Before issuing this command, set the logical level of pulses and pulse width by the automatic home search mode setting 2
command (24h). See chapter 2.5.2 and 2.5.4 for details.
7.8.4
Timer-Start
Code
Command
73
h
Timer-start
This command starts a timer.
When a timer is started by this command, the current timer value (CT) starts to count up from 0, and when the count reaches the
value specified by the timer value (TM), then the timer is up.
A timer can be used repeatedly after the time is up. To repeat a timer, set D14 bit (TMMD) of WR3 register to 1.
For more details of the timer, see chapter 2.9.
7.8.5
Timer-Stop
Code
Command
74
h
Timer-stop
This command stops a timer.
If a timer is stopped before it expires, the current timer value (CT) returns to 0. And if the timer is started again, it counts up from
0.
7.8.6
Start of Split Pulse
Code
Command
75
h
Start of split pulse
This command outputs split pulses.
Split pulses are output from the nSPLTP output pin during the driving.
SPLIT bit of Page1 of RR3 register which indicates the split pulse is in operation becomes 1 by issuing start of split pulse
command.
Before issuing this command, each parameter such as a split pulse length must be set appropriately.
For more details of each parameter for the split pulse, see chapter 2.7.