7.2.9
Circular Center Point Setting
Code
Command
Symbol
Data Range
Data Length
(byte)
08
h
Circular center point setting
CT
-1,073,741,823
~
+1,073,741,823
4
“CT” is the parameter setting the center point in circular and helical interpolation driving. The coordinates of center point should
be set the signed relative value to the current position.
7.2.10 Logical Position Counter Setting
Code
Command
Symbol
Data Range
Data Length
(byte)
09
h
Logical position counter setting
LP
-2,147,483,648
~
+2,147,483,647
4
“LP” is the parameter setting the value of logical position counter.
Logical position counter counts Up / Down according t
o the +/− direction pulse output.
A logical position counter setting value can be written anytime, and read by logical position counter reading command (30h)
anytime.
7.2.11 Real Position Counter Setting
Code
Command
Symbol
Data Range
Data Length
(byte)
0A
h
Real position counter setting
RP
-2,147,483,648
~
+2,147,483,647
4
“RP” is the parameter setting the value of real position counter.
Real position counter counts Up / Down according to encoder input pulse.
A real position counter setting value can be written anytime, and read by real position counter reading command (31h) anytime.
7.2.12 Software Limit + Setting
Code
Command
Symbol
Data Range
Data Length
(byte)
0B
h
Software limit + setting
SP
-2,147,483,648
~
+2,147,483,647
4
“SP” is the parameter setting the value of + direction software limit SLMT+ register.
Enable / disable, an object to set, and stop mode of software limit can be set by WR2 register.
A software limit SLMT+ register setting value can be written anytime.