![Nova Electronics MCX514 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/nova-electronics/mcx514/mcx514_user-manual_1710400025.webp)
NOVA electronics Inc.
MCX514 -
12
-
12
-
Position Counter
Logical Position Counter
Count Range
:
-2,147,483,648
~
+2,147,483,647
drive pulse
*5
Real Position Counter
Count Range
:
-2,147,483,648
~
+2,147,483,647
drive pulse
*5
Variable Ring
Possible to set the count maximum value of each counter
Software Limit
Setting Range
-2,147,483,648
~
+2,147,483,647
pulse
Stop Mode
Decelerating / Instant stop selectable
Multi-Purpose
Register
Bit Length,
Number of Registers
32-bit length
4 registers per axis
Uses
Compare with position, speed and timer value,
load data such as position and speed, and save data such as current
position, speed and timer value
Timer
Number of timers
1 per axis
Setting Range
1
~
2,147,483,647μsec
Split Pulse
Number of signals
1 per axis
Split Length
2
~
65,535 drive pulse
*6
Split Pulse Width
1
~
65,534 drive pulse
Split Pulse Number
1
~
65,535, or up to infinity
Automatic Home
Search
Sequence
STEP1 high-speed home search
→ STEP2 low-speed home search
→ STEP3 encoder Z-phase search → STEP4 offset drive
・
Enable / Disable each step and search signal / direction are
selectable
Deviation Counter Clear
Output
Clear pulse width within the range of
10μ
~
20
m
sec,
Logical level selectable
Timer between Steps
1msec
~
1,000msec selectable
Synchronous Action
Number of Sets
4 sets per axis
*7
Activation Factor
・
When multi-purpose register comparison changed
・
Comparative object
:
logical/real position counter value,
current drive speed, current timer value
・
Comparison condition
:
≧,>,=,<
・
When a timer is up
・
Start/Termination of driving, Start/Termination of driving at constant
speed area in acceleration / deceleration driving
・
Start/Termination of split pulse, Output of split pulse
・
nPIOm signal
↑/↓, nPIOm+4 signal Low and nPIOm signal ↑,
nPIOm+4 signal Hi and nPIOm signal
↑,
nPIOm+4 signal Low and nPIOm signal
↓,
nPIOm+4 signal Hi and nPIOm
signal ↓ (m:0,1,2,3)
・
Activation command
Action
・
Load value (
MRm→setting value)
:
Drive speed,
Drive pulse number (Finish point), Split length, Split pulse width,
Logical/Real position counter value, Initial speed, Acceleration
・
Save value (
MRm←current value)
:
Logical/Real position counter
value, Current timer value, Current drive speed,
Current acceleration / deceleration
・
Synchronous pulse output to the external
・
Start of relative/absolute position driving, Start of
+
/
-
direction
continuous driving, Start of relative/absolute position driving at the
position set by MRm
・
Decelerating stop / Instant stop, Speed increase/decrease,
Timer-start/stop, Start / Termination of split pulse
Other SYNC Activation
Activation of other 3 sets actions can be set.
Another Axis SYNC0 Activation
Activation of another SYNC0 action can be set.
Repeat
Synchronous action can be operated once/repeatedly.