NOVA electronics Inc. MCX514 -
197
-
197
-
7.2.20 Multi-Purpose Register 3 Setting
Code
Command
Symbol
Data Range
Data Length
(byte)
13
h
Multi-purpose register 3 setting
MR3
-2,147,483,648
~
+2,147,483,647
4
“MR3” is the parameter setting the value of multi-purpose register 3.
Multi-purpose register is used for comparison of position, speed, timer value and large or small, and load / save of each parameter
as a synchronous action. Comparison result is used for outputting of comparison output signal, synchronous action activation and
generating an interrupt.
A multi-purpose register MR3 setting value can be written anytime, and read by multi-purpose register 3 reading command (37h)
anytime.
7.2.21 Home Search Speed Setting
Code
Command
Symbol
Data Range
Data Length
(byte)
14
h
Home search speed setting
HV
1
~
8,000,000
4
“HV” is the parameter setting the low-speed home search speed that is applied in Steps 2 and 3.
The unit of the setting value is pps.
Home Search Speed = HV [pps]
Set a value lower than the initial speed (SV) to stop driving immediately when a search signal becomes active.
See chapter 2.5 for details of automatic home search.
7.2.22 Speed Increasing / Decreasing Value Setting
Code
Command
Symbol
Data Range
Data Length
(byte)
15
h
Speed increasing / decreasing value
setting
IV
1
~
1,000,000
4
“IV” is the parameter setting the value to increase / decrease the current drive speed by speed increase command (70h) and speed
decrease command (71h) during the driving. The unit of the setting value is pps.
Speed Increasing / Decreasing Value = IV [pps]
In acceleration / deceleration driving, the speed increase / decrease command is written at constant speed area, acceleration /
deceleration is performed until it reaches the drive speed by this speed increasing /decreasing value setting, and then constant
speed driving will start again.