Appendix B: Test forms
B-5
Wireless Solutions
DualMode 800 Enclosure
Maintenance Manual
MTX08
DRU checks — Receive tests (Chapter 11)
Cell:
Date:
Performed by:
RF Frame:
TRU Shelf:
TRU receive tests
TRU 1
TRU 2
TRU 3
TRU 4
TRU 5
TRU 6
TRU 7
TRU 8
Serial number:
Channel number:
RX frequency (MHz):
EEPROM CRC check:
Receive sensitivity (Level):
Less than -105 dBm
RX/TX audio sensitivity:
Deviation 2.6 to 3.2 kHz
Receive audio level:
Level -17.0 to -19.0 dBm
RSSI curve:
Input (dBm)
RSSI (dBm)
-60
-66 to -76
-70
-76 to -86
-80
-86 to -96
-84
-90 to -100
-90
-96 to -106
-100
-106 to -116
SAT detect 5970 Hz (level
lost all): Less than -105 dBm
SAT detect 6000 Hz (level
lost all): Less than -105 dBm
SAT detect 6030 Hz (level
lost all): Less than -105 dBm
ST detect 10 kHz (level lost
all): Less than -105 dBm
Содержание DualMode 800
Страница 2: ......
Страница 4: ......
Страница 6: ...vi Publication history Nortel Networks Confidential 411 2051 500 Draft 00 01 November 1999...
Страница 82: ...2 20 Periodic maintenance 411 2051 500 Draft 00 01 November 1999...
Страница 90: ...3 8 Test equipment and precautions 411 2051 500 Draft 00 01 November 1999...
Страница 100: ...5 6 Master Oscillator tests 411 2051 500 Draft 00 01 November 1999...
Страница 106: ...6 6 Antenna and transmission line tests 411 2051 500 Draft 00 01 November 1999...
Страница 116: ...8 4 Alarm Control Unit ACU tests 411 2051 500 Draft 00 01 November 1999...
Страница 138: ...10 2 ICRM tests 411 2051 500 Draft 00 01 November 1999...
Страница 200: ...12 10 Enclosure maintenance 411 2051 500 Draft 00 01 November 1999...
Страница 208: ...A 8 Appendix A Frequency table 411 2051 500 Draft 00 01 November 1999...
Страница 215: ......