Nortel Networks Confidential
Transmit Receive Unit (TRU)
1-37
Wireless Solutions
DualMode 800 Enclosure Maintenance Manual
MTX08
Name
Terminal
Command
Personality
Allowed
Description
DRU Reset
Execute RESET
Any
Causes the DRU to completely reset all of its
systems and restart processing at the ROM
level.
DRU Restart
Execute
RESTARTFLASH
Any
Causes the DRU to restart processing within
the flash load.
Enable
Fullscreen Mode
Set FS on
VCH, CCH,
ALR, or
Maint.
Enables the Fullscreen mode of the terminal
interface.
Fault Simulation
Run FAULTSIM
fault
Any
Simulates the specified fault by sending the
fault up to the ICP.
Installation
Calibration
Set INSTCAL
dB_level
VCH,
CCH, or
TTC
Provides the capability to correct the power
reading (range:
±
100dB; 0.01 dB resolution).
LAPD Timeout
Control
Set LT|
LAPDTIMEOUT
on|off
Any
Enables/disables the LAPD timeout. If the TRU
detects loss of the LAPD link, it resets itself
after 10-12 seconds. With the LAPD timeout set
off, the TRU does not reset, which is necessary
for stand alone testing.
Message
Injection
Run INJECT from|to
ICP|MPA|DSP bytes
Note:
MPA not
supported by Urban
Any
Injects the specified message trace (bytes) at
the specified interface point in the specified
direction.
Message Trace
Control
Set TRACE from|to
ICP|MPA|DSP
on|off
Note:
MPA not
supported by Urban
Any
Enables/disables message trace at the
specified interface point in the specified
direction.
MPA LED On/Off
(Not used in
Urban)
Set MPALED on/off
Any
Turns the fault indicator LED on MPA module
on or off.
Nominal
Application Gain
Set NOMGAIN
dB_level
VCH,
CCH, or
TTC
Provides a method of compensating for nominal
losses or gains as a result of cell site hardware
used with the TRU (range:
±
100dB; 0.01 dB
resolution).
OM Simulation
Run OMSIM omtype Any
Pegs the occurrence of the specified OM.
- continued -
Table 1-4
Command line mode maintenance commands (continued)
Содержание DualMode 800
Страница 2: ......
Страница 4: ......
Страница 6: ...vi Publication history Nortel Networks Confidential 411 2051 500 Draft 00 01 November 1999...
Страница 82: ...2 20 Periodic maintenance 411 2051 500 Draft 00 01 November 1999...
Страница 90: ...3 8 Test equipment and precautions 411 2051 500 Draft 00 01 November 1999...
Страница 100: ...5 6 Master Oscillator tests 411 2051 500 Draft 00 01 November 1999...
Страница 106: ...6 6 Antenna and transmission line tests 411 2051 500 Draft 00 01 November 1999...
Страница 116: ...8 4 Alarm Control Unit ACU tests 411 2051 500 Draft 00 01 November 1999...
Страница 138: ...10 2 ICRM tests 411 2051 500 Draft 00 01 November 1999...
Страница 200: ...12 10 Enclosure maintenance 411 2051 500 Draft 00 01 November 1999...
Страница 208: ...A 8 Appendix A Frequency table 411 2051 500 Draft 00 01 November 1999...
Страница 215: ......