Nortel Networks Confidential
Transmit Receive Unit (TRU)
1-39
Wireless Solutions
DualMode 800 Enclosure Maintenance Manual
MTX08
Name
Terminal
Command
Personality
Allowed
Description
Set Mobile
Loopback
Set RFLOOP on|off
VCH, CCH
Enables/disables the RF loopback capability of
the TRU.
Set Multicoupler
Gain
Set MCGAIN A|B
dB_loss1 dB_loss2
dB_loss3
Any
Sets the compensation for the gain through the
antenna and multicoupler system for the
antennas connected to the specified path.
Set PA Maximum
Power Level
Set MAXTXPOW
dBm_level
VCH, CCH,
or TTC
Sets the output power of the MCPA to the
specified dBm value with a resolution of 0.01
dB.
Set PA Power
index
Set TXPOWIDX
index
VCH, CCH,
or TTC
Sets the MCPA power to the specified dpc
index. The index is an integer (from 0 to 7) that
corresponds to a dBm power level.
Set PA Power
Step
Set TXPOWSTEP
dB_adjustment
VCH, CCH,
or TTC
Adjusts the output power DPC stepsize of the
MCPA by the amount specified. The power step
value can be 0 to 100 dB in steps of 0.01 dB.
Set Personality
Set PERS
ACC|ALR|AVC|
TLR|TTC
Note:
The TRU3
supports DCCH and
TTC only
Any
The TRU is reset and set to the given
personality. The personality may be IS-54 CCH,
AMPS LCR, AMPS VCH, TDMA LCR, or TDMA
TTC.
Set Transmission Set TRANSMIT
on|off
VCH, CCH,
or TTC
Enables/disables the transmitter in the TRU.
This command functions the same as the ”Set
PA on|off” command.
SWERR
Simulation
Run SWERRSIM
class code
Any
Logs an artificial software error.
Transmitter Tone
Generation
Control
Set RFGEN on|off
VCH
Turns on/off generation of transmitter test tone.
Tx Audio On/Off
Set TXAUDIO on|off VCH
Turns on (unmute) or off (mute) the transceiver
audio output downstream (to the mobile).
- End -
Table 1-4
Command line mode maintenance commands (continued)
Содержание DualMode 800
Страница 2: ......
Страница 4: ......
Страница 6: ...vi Publication history Nortel Networks Confidential 411 2051 500 Draft 00 01 November 1999...
Страница 82: ...2 20 Periodic maintenance 411 2051 500 Draft 00 01 November 1999...
Страница 90: ...3 8 Test equipment and precautions 411 2051 500 Draft 00 01 November 1999...
Страница 100: ...5 6 Master Oscillator tests 411 2051 500 Draft 00 01 November 1999...
Страница 106: ...6 6 Antenna and transmission line tests 411 2051 500 Draft 00 01 November 1999...
Страница 116: ...8 4 Alarm Control Unit ACU tests 411 2051 500 Draft 00 01 November 1999...
Страница 138: ...10 2 ICRM tests 411 2051 500 Draft 00 01 November 1999...
Страница 200: ...12 10 Enclosure maintenance 411 2051 500 Draft 00 01 November 1999...
Страница 208: ...A 8 Appendix A Frequency table 411 2051 500 Draft 00 01 November 1999...
Страница 215: ......