7-1
Wireless Solutions
DualMode 800 Enclosure
Maintenance Manual
MTX08
Enhanced Receive Multicoupler (ERMC)
tests
7
ERMC description
The Enhanced Receive MultiCoupler (ERMC) modifies the receive RF signal
for the front-end of the TRU shelf transceivers. The ERMC provides
selectivity, signal gain and signal distribution so that the receive signal is
adequate for the transceiver front-end.
ERMC overall gain measurement test
This test is required for a cell site suspected of faulty operation. The test is
service affecting.
Step
Action
Observation
1
Notify the Control Center to OFFLINE the
cell site.
2
Disconnect the antenna feed cables from the
selectivity filter inputs.
3
Disconnect the cable from the ERMC splitter
port to be tested.
4
Using a 50-ohm cable, connect the
communications monitor Duplex Output port
to the selectivity filter input of the ERMC
(either A or B side). See Figure 7-1.
5
Using a 50-ohm cable, connect the
communications monitor T/R port to one of
the splitter ports corresponding to the A or B
path selected. See Figure 7-1.
- continued -
Содержание DualMode 800
Страница 2: ......
Страница 4: ......
Страница 6: ...vi Publication history Nortel Networks Confidential 411 2051 500 Draft 00 01 November 1999...
Страница 82: ...2 20 Periodic maintenance 411 2051 500 Draft 00 01 November 1999...
Страница 90: ...3 8 Test equipment and precautions 411 2051 500 Draft 00 01 November 1999...
Страница 100: ...5 6 Master Oscillator tests 411 2051 500 Draft 00 01 November 1999...
Страница 106: ...6 6 Antenna and transmission line tests 411 2051 500 Draft 00 01 November 1999...
Страница 116: ...8 4 Alarm Control Unit ACU tests 411 2051 500 Draft 00 01 November 1999...
Страница 138: ...10 2 ICRM tests 411 2051 500 Draft 00 01 November 1999...
Страница 200: ...12 10 Enclosure maintenance 411 2051 500 Draft 00 01 November 1999...
Страница 208: ...A 8 Appendix A Frequency table 411 2051 500 Draft 00 01 November 1999...
Страница 215: ......