11-36
DRU tests
411-2051-500
Draft
00.01
November 1999
ST detect test
This test ensures that the DRU meets the minimum requirement of detecting a
Signaling Tone signal.
13
Reduce the level of the RF signal until a “N”
is indicated at the RX SAT status on the
screen.
The RX SAT status on the screen shows:
RX SAT: N
14
Check the RF signal level on the
communications monitor.
The RF signal level must be:
less than -105 dBm
15
Record the RF signal level on the test forms.
- End -
Step
Action
Observation
1
Ensure that the DRU configurations are as
listed in Table 11-1 for the ST detect test.
2
Use the P command to query the ST signal.
>P
The DRU will prompt for the signal to query:
Enter R, SAT, ST, or A
3
Enter the “ST” option to query the ST signal.
>ST
The RX ST status shows:
N
The output message shows:
continuing Query..(hit return
to exit)
4
Using the communications monitor, apply a
-90 dBm on-channel RF signal modulated
with a 10 kHz tone at
±
7.2 kHz deviation to
the DRU under test.
The RX ST status on the screen should
show:
RX ST: Y
5
Reduce the level of the RF signal until a “N”
is indicated at the RX ST status on the
terminal screen.
The RX ST status on the screen shows:
RX ST: N
6
Check the RF signal level on the
communications monitor.
The RF signal level must be:
less than -105 dBm
7
Record the RF signal level on the test forms.
8
Press the “Return” key from the terminal to
discontinue the measurement.
The output message will show:
Query Status is OFF
Step
Action
Observation
Содержание DualMode 800
Страница 2: ......
Страница 4: ......
Страница 6: ...vi Publication history Nortel Networks Confidential 411 2051 500 Draft 00 01 November 1999...
Страница 82: ...2 20 Periodic maintenance 411 2051 500 Draft 00 01 November 1999...
Страница 90: ...3 8 Test equipment and precautions 411 2051 500 Draft 00 01 November 1999...
Страница 100: ...5 6 Master Oscillator tests 411 2051 500 Draft 00 01 November 1999...
Страница 106: ...6 6 Antenna and transmission line tests 411 2051 500 Draft 00 01 November 1999...
Страница 116: ...8 4 Alarm Control Unit ACU tests 411 2051 500 Draft 00 01 November 1999...
Страница 138: ...10 2 ICRM tests 411 2051 500 Draft 00 01 November 1999...
Страница 200: ...12 10 Enclosure maintenance 411 2051 500 Draft 00 01 November 1999...
Страница 208: ...A 8 Appendix A Frequency table 411 2051 500 Draft 00 01 November 1999...
Страница 215: ......