Thank you for selecting Salsbury’s

 12" wide

 vented single tier lockers.  These instructions are intended to assist you in assembling the lockers.  Note that a 6 feet high locker is shown.  

Hole locations on the 5 feet high locker are different.  Assembly of the various locker components will be with #10 - 24 x 3/8” long slot less screws and #10 nuts (provided).  Loosely 
fasten a screw and a nut into every set of mating holes with the screw heads positioned on the outside of the locker or on the exposed surface. 

One Wide Locker Assembly 

Step 1

:  Attach the top shelf, bottom shelf, and the first single coat hook to the back 

panel.   

Step 2:

  Turn the back panel on its back with the shelves pointing upward.  Attach the

first side panel, the left rear leg, and the hat shelf to the assembly from Step 1.  On 12” 
and 15” deep lockers attach the double coat hook to the bottom of the hat shelf and 
attach a second single coat hook to the first side panel.  On 18” deep lockers omit the 
double coat hook and substitute a single coat hook with a double bend (not shown) 
instead of the second single coat hook (this will accommodate the coat rod). 

Step 3:

  Attach the second side panel and the right rear leg to the assembly of Step 2.

On  12”  and  15”  deep  lockers  attach  a  third  single  coat  hook.    On  18”  deep  lockers 
substitute  a  single  coat  hook  with  a  double  bend  for  the  third  single  coat  hook  and 
install the coat rod as shown on page 3.  The locker chassis is now complete. 

Step 4: 

 Attach the pre-assembled door frame onto the assembly of Step 3.

Step 5:

  Tighten all fasteners checking for squareness of the locker while tightening.

Attach optional sloping hood, end bases or front base (see pages 4 and 5). 

Step 6:

  Place the locker in the installed location and anchor to the floor, wall, or to

both.    Individual  job  conditions  will  dictate  the  type  of  fastening  anchors  to  use  (not 
provided).  

Step 7:

  Fasten all lockers in a row together by installing fasteners provided through

the side panels.  Installation is now complete. 