6-4
Antenna and transmission line tests
411-2051-500
Draft
00.01
November 1999
Thruline wattmeter method (Antenna return loss)
This is a service affecting test using a Thruline Wattmeter. It can be used with
transmit antennas only. Ensure that all transmitters are OFF before
inserting the Thruline in the transmission path.
Antenna sweep
This is a service affecting test. Ensure that all transmitters are OFF before
disconnecting the antenna cable.
Step
Action
Observation
1
Connect the Thruline between the duplexer
and the antenna.
2
Measure the forward and reverse power
using the appropriate element with one or
more transmitters turned on.
Reflected power less than 4% of forward
power
Step
Action
Observation
1
Set up and calibrate a network analyzer
(HP8753C or equivalent) to sweep 823 to
895 MHz.
2
Notify the Control Center to OFFLINE the
cell site.
3
Disconnect the antenna jumper cable.
(Located at the duplexer for the tx/rx antenna
or at the RMC for the diversity receive
antenna.)
- continued -
Содержание DualMode 800
Страница 2: ......
Страница 4: ......
Страница 6: ...vi Publication history Nortel Networks Confidential 411 2051 500 Draft 00 01 November 1999...
Страница 82: ...2 20 Periodic maintenance 411 2051 500 Draft 00 01 November 1999...
Страница 90: ...3 8 Test equipment and precautions 411 2051 500 Draft 00 01 November 1999...
Страница 100: ...5 6 Master Oscillator tests 411 2051 500 Draft 00 01 November 1999...
Страница 106: ...6 6 Antenna and transmission line tests 411 2051 500 Draft 00 01 November 1999...
Страница 116: ...8 4 Alarm Control Unit ACU tests 411 2051 500 Draft 00 01 November 1999...
Страница 138: ...10 2 ICRM tests 411 2051 500 Draft 00 01 November 1999...
Страница 200: ...12 10 Enclosure maintenance 411 2051 500 Draft 00 01 November 1999...
Страница 208: ...A 8 Appendix A Frequency table 411 2051 500 Draft 00 01 November 1999...
Страница 215: ......