1-38
Equipment operation
Nortel Networks Confidential
411-2051-500
Draft
00.01
November 1999
Name
Terminal
Command
Personality
Allowed
Description
PA On/Off
Set PA on|off
VCH, CCH,
or TTC
Turns the power amplifier (transmitter) on/off.
PA LED On/Off
Set PALED on/off
Any
Turns the fault indicator LED on MCPA module
on or off.
PA Type
Set PATYPE type
Note:
DualMode
800 Enclosure
supports only the
NONE mode.
VCH, CCH,
or TTC
Allows for the setting of the type of PA being
used: MPA indicates that a MPA is being used;
SCLPA indicates that a SCLPA is being used;
NONE indicates that no PA is used - the TRU is
using its own internal PA to output a modulated
signal.
Path Antenna
Select
Set DIVPORT
path_A_port:1|2|3
path_B_port:4|5|6
VCH
Establishes a ”nailed” connection for the given
antenna.
Receive Path
Selection
Set PATH
A|B|CURRENT|DIV
VCH
Set the diversity receiver to be either the A(0) or
B(1) path, or enable diversity switching (2).
Receive SAT
Color Code
Set RXSATCC
detector cc
VCH
Configures the SAT detector to look for
specified color code.
Rx Audio On/Off
Set RXAUDIO
on|off
VCH
Turns on (unmute) or off (mute) the transceiver
audio output upstream (to the ICRM).
SAT Frequency
Select
Set TXSATCC cc
VCH
Selects frequency to be used for SAT
generation.
SAT Generation
On/Off
Set SATGEN on|off
VCH
Turns on/off generation of supervisory audio
tone.
Set Audio
Sensitivity
Set AUDSENS
TX|RX dBm_value
VCH
Sets the audio sensitivity for the transmit or
receive paths.
Set C-Side
Loopback
Set BCHLOOP
on|off
All but
maint.
Enables/disables TCM loopback to the ICRM.
Set C-Side Tone
Generation
Set BCHTONE
on|off
VCH
Enables/disables tone generation to the ICRM.
Set Channel
Set CHANNEL chan All but
maint.
Sets the receive and transmit channel to the
given value.
- continued -
Table 1-4
Command line mode maintenance commands (continued)
Содержание DualMode 800
Страница 2: ......
Страница 4: ......
Страница 6: ...vi Publication history Nortel Networks Confidential 411 2051 500 Draft 00 01 November 1999...
Страница 82: ...2 20 Periodic maintenance 411 2051 500 Draft 00 01 November 1999...
Страница 90: ...3 8 Test equipment and precautions 411 2051 500 Draft 00 01 November 1999...
Страница 100: ...5 6 Master Oscillator tests 411 2051 500 Draft 00 01 November 1999...
Страница 106: ...6 6 Antenna and transmission line tests 411 2051 500 Draft 00 01 November 1999...
Страница 116: ...8 4 Alarm Control Unit ACU tests 411 2051 500 Draft 00 01 November 1999...
Страница 138: ...10 2 ICRM tests 411 2051 500 Draft 00 01 November 1999...
Страница 200: ...12 10 Enclosure maintenance 411 2051 500 Draft 00 01 November 1999...
Страница 208: ...A 8 Appendix A Frequency table 411 2051 500 Draft 00 01 November 1999...
Страница 215: ......