11-6
DRU tests
411-2051-500
Draft
00.01
November 1999
2. Place the TRU into the command line mode by pressing the “Break” key
on the interface terminal. The terminal will display the following:
TRU Terminal Interface
Copyright 1990,1991 Bell Northern Research, Inc.
>
3. To place the TRU into the fullscreen monitor mode, enter:
>SET LT OFF
(disables the LAPD timeout)
>SET FS ON
(invokes fullscreen display)
This places the TRU into the fullscreen AMPS mode (refer to Figure 1-8).
TRU EEPROM CRC Check
4. Check the top right corner of the screen and verify that the EEPROM
CRC Check has passed. The EEPROM CRC Check on the screen (refer to
Figure 1-8 in Chapter 1, Equipment operation) will show:
EEPROM CRC Check: PASSED
Record the result. If the check fails, replace the TRU.
5. Disconnect the interface terminal from the TRU under test.
DRU configurations for analog tests
The Transmit Receive Unit (TRU) must be correctly configured for each test.
This section covers the general test set-ups for the TRU.
Nominal Application Gain
In a DualMode 800 Enclosure, all TRUs are set to “patype none” mode
during installation. In this mode, the nominal application gain is set to a
default value of -12 dB and the TRU maximum transmit power is set to a
default value of +15 dBm. Do not change these default settings during the
tests.
With default settings in the “patype none” mode, the output of the TRU is set
to [+15 - (-12)] = +27 dBm at the TRU backplane. Therefore, when checking
the TRU output with the “query pastatus” command, please remember that
the +15 dBm TRU output has been compansated for by the -12 dB norminal
application gain to give an actual TRU output of +27 dBm at default.
Содержание DualMode 800
Страница 2: ......
Страница 4: ......
Страница 6: ...vi Publication history Nortel Networks Confidential 411 2051 500 Draft 00 01 November 1999...
Страница 82: ...2 20 Periodic maintenance 411 2051 500 Draft 00 01 November 1999...
Страница 90: ...3 8 Test equipment and precautions 411 2051 500 Draft 00 01 November 1999...
Страница 100: ...5 6 Master Oscillator tests 411 2051 500 Draft 00 01 November 1999...
Страница 106: ...6 6 Antenna and transmission line tests 411 2051 500 Draft 00 01 November 1999...
Страница 116: ...8 4 Alarm Control Unit ACU tests 411 2051 500 Draft 00 01 November 1999...
Страница 138: ...10 2 ICRM tests 411 2051 500 Draft 00 01 November 1999...
Страница 200: ...12 10 Enclosure maintenance 411 2051 500 Draft 00 01 November 1999...
Страница 208: ...A 8 Appendix A Frequency table 411 2051 500 Draft 00 01 November 1999...
Страница 215: ......