Frame Type
Select the frame type for this ACE. These frame types are mutually exclusive.
Any:
Any frame can match this ACE.
Ethernet Type:
Only Ethernet Type frames can match this ACE. The IEEE 802.3
describes the value of Length/Type Field specifications to be greater than or equal to
1536 decimal (equal to 0600 hexadecimal).
ARP:
Only ARP frames can match this ACE. Notice the ARP frames won't match the
ACE with ethernet type.
IPv4:
Only IPv4 frames can match this ACE. Notice the IPv4 frames won't match the
ACE with ethernet type.
IPv6:
Only IPv6 frames can match this ACE. Notice the IPv6 frames won't match the
ACE with Ethernet type.
Action
Specify the action to take with a frame that hits this ACE.
Permit:
The frame that hits this ACE is granted permission for the ACE operation.
Deny:
The frame that hits this ACE is dropped.
Rate Limiter
Specify the rate limiter in number of base units. The allowed range is 1 to 16. Disabled
indicates that the rate limiter operation is disabled.
Port Redirect
Frames that hit the ACE are redirected to the port number specified here. The allowed
range is the same as the switch port number range. Disabled indicates that the port redirect
operation is disabled and the specific port number of 'Port Redirect' can't be set when
action is permitted.
Logging
Specify the logging operation of the ACE. The allowed values are:
Enabled:
Frames matching the ACE are stored in the System Log.
Disabled:
Frames matching the ACE are not logged.
Please note that the System Log memory size and logging rate is limited.
Shutdown
Specify the port shut down operation of the ACE. The allowed values are:
Enabled:
If a frame matches the ACE, the ingress port will be disabled.
Disabled:
Port shut down is disabled for the ACE.
Counter