3.4.2. Maintenance - Factory Defaults
You can reset the configuration of the stack on this page. Only the IP configuration is
retained.
The new configuration is available immediately, which means that no restart is necessary.
Buttons
Yes:
Click to reset the configuration to Factory Defaults.
No:
Click to return to the Port State page without resetting the configuration.
Note:
Restoring factory default can also be performed by making a physical loopback
between port 1 and port 2 within the first minute from switch reboot. In the first minute after
boot, 'loopback' packets will be transmitted at port 1. If a 'loopback' packet is received at port
2 the switch will do a restore to default