9.5 Standby Function Control Register
(1) Oscillation stabilization time selection register (OSTS)
The wait time from releasing the stop mode until the oscillation stabilizes is controlled by the oscillation
stabilization time selection register (OSTS).
OSTS is set by an 8-bit memory manipulation instruction.
RESET input sets OSTS to 04H.
After reset: 04H
R/W
Address: FFFFF380H
7
6
5
4
3
2
1
0
OSTS
0
0
0
0
0
OSTS2
OSTS1
OSTS0
Oscillation stabilization time selection
f
XX
OSTS2
OSTS1
OSTS0
Clock
20 MHz
Note
12.58 MHz
0
0
0
2
14
/f
XX
819.2
µ
s
1.3 ms
0
0
1
2
16
/f
XX
3.3 ms
5.2 ms
0
1
0
2
17
/f
XX
6.6 ms
10.4 ms
0
1
1
2
18
/f
XX
13.1 ms
20.8 ms
1
0
0
2
19
/f
XX
(after reset)
26.2 ms
41.6 ms
Other than above
Setting prohibited
Note
Only in the V850/SB1.
Caution
The wait time at the release of the STOP mode does not include the time (“a” in the figure below)
until clock oscillation starts after releasing the STOP mode when RESET is input or an interrupt
is generated.
Vss