CHAPTER 10 SERIAL INTERFACE FUNCTION
User’s Manual U13850EJ6V0UD
301
(c) Start ~ Code ~ Data ~ Data ~ Stop (extension code transmission)
<1> When WTIMn = 0
SPTn = 1
↓
ST
AD6 to AD0
RW
AK
D7 to D0
AK
D7 to D0
AK
SP
▲
1
▲
2
▲
3
▲
4
∆
5
▲
1: IICSn = 1010X110B
▲
2: IICSn = 1010X000B
▲
3: IICSn = 1010X000B (WTIMn = 1)
▲
4: IICSn = 1010XX00B
∆
5: IICSn = 00000001B
Remark
▲
: Always generated
∆
:
Generated only when SPIEn = 1
X:
don’t care
n = 0, 1
<2> When WTIMn = 1
SPTn = 1
↓
ST
AD6 to AD0
RW
AK
D7 to D0
AK
D7 to D0
AK
SP
▲
1
▲
2
▲
3
∆
4
▲
1: IICSn = 1010X110B
▲
2: IICSn = 1010X100B
▲
3: IICSn = 1010XX00B
∆
4: IICSn = 00000001B
Remark
▲
: Always generated
∆
:
Generated only when SPIEn = 1
X:
don’t care
n = 0, 1