CHAPTER 17 SERIAL INTERFACE IIC0 (
µ
PD780344Y, 780354Y SUBSERIES ONLY)
336
User’s Manual U15798EJ2V0UD
(d) Start ~ Code ~ Data ~ Start ~ Address ~ Data ~ Stop
(i)
When WTIM0 = 0 (after restart, does not match with address (= not extension code))
ST
AD6 to AD0 RW
AK
D7 to D0
AK
ST
AD6 to AD0 RW
AK
D7 to D0
AK
SP
1
2
3
4
1: IICS0 = 0010
×
010B
2: IICS0 = 0010
×
000B
3: IICS0 = 00000
×
10B
4: IICS0 = 00000001B
Remark
: Always generated
: Generated only when SPIE0 = 1
×
: Don’t care
(ii) When WTIM0 = 1 (after restart, does not match with address (= not extension code))
ST
AD6 to AD0 RW
AK
D7 to D0
AK
ST
AD6 to AD0 RW
AK
D7 to D0
AK
SP
1
2
3
4
1: IICS0 = 0010
×
010B
2: IICS0 = 0010
×
110B
3: IICS0 = 0010
××
00B
4: IICS0 = 00000001B
Remark
: Always generated
: Generated only when SPIE0 = 1
×
: Don’t care
(4) Operation without communication
(a) Start ~ Code ~ Data ~ Data ~ Stop
ST
AD6 to AD0 RW
AK
D7 to D0
AK
D7 to D0
AK
SP
1
1: IICS0 = 00000001B
Remark
: Generated only when SPIE0 = 1