296
CHAPTER 16 SERIAL INTERFACE UART0
User’s Manual U15798EJ2V0UD
(b) Asynchronous serial interface status register 0 (ASIS0)
ASIS0 can be read by an 8-bit memory manipulation instruction.
RESET input sets the value of this register to 00H.
Address: FFA1H After reset: 00H R
Symbol
7
6
5
4
3
2
1
0
ASIS0
0
0
0
0
0
PE0
FE0
OVE0
PE0
Parity error flag
0
No parity error
1
Parity error
(Transmit data parity not matched)
FE0
Framing error flag
0
No framing error
1
Framing error
Note 1
(Stop bit not detected)
OVE0
Overrun error flag
0
No overrun error
1
Overrun error
Note 2
(Next receive operation was completed before data was read from receive buffer register
0 (RXB0))
Notes 1.
Even if a stop bit length is set to 2 bits by setting bit 2 (SL0) in asynchronous serial interface mode
register 0 (ASIM0), stop bit detection during a receive operation only applies to a stop bit length
of 1 bit.
2.
Once an overrun error has occurred, further overrun errors will occur until the contents of RXB0
are read.