312
CHAPTER 17 SERIAL INTERFACE IIC0 (
µ
PD780344Y, 780354Y SUBSERIES ONLY)
User’s Manual U15798EJ2V0UD
Figure 17-3. Format of IIC Control Register 0 (IICC0) (2/3)
WTIM0
Control of wait and interrupt request generation
0
Interrupt request is generated at the eighth clock’s falling edge.
Master mode: After output of eight clocks, clock output is set to low level and wait is set.
Slave mode:
After input of eight clocks, the clock is set to low level and wait is set for master device.
1
Interrupt request is generated at the ninth clock’s falling edge.
Master mode: After output of nine clocks, clock output is set to low level and wait is set.
Slave mode:
After input of nine clocks, the clock is set to low level and wait is set for master device.
This bit’s setting is invalid during an address transfer and is valid after the transfer is completed. When in master
mode, a wait is inserted at the falling edge of the ninth clock during address transfers. For a slave device that
has received a local address, a wait is inserted at the falling edge of the ninth clock after an ACK signal is issued.
When the slave device has received an extension code, a wait is inserted at the falling edge of the eighth clock.
Condition for clearing (WTIM0 = 0)
Note
Condition for setting (WTIM0 = 1)
• Cleared by instruction
• Set by instruction
• When RESET is input
ACKE0
Acknowledge control
0
Disable acknowledge.
1
Enable acknowledge. During the ninth clock period, the SDA0 line is set to low level. However, the
ACK is invalid during address transfers and is valid when EXC0 = 1.
Condition for clearing (ACKE0 = 0)
Note
Condition for setting (ACKE0 = 1)
• Cleared by instruction
• Set by instruction
• When RESET is input
STT0
Start condition trigger
0
Does not generate a start condition.
1
When bus is released (during STOP mode):
Generates a start condition (for starting as master). The SDA0 line is changed from high level to
low level and then the start condition is generated. Next, after the rated amount of time has
elapsed, SCL0 is changed to low level.
When bus is not used:
This trigger functions as a start condition reserve flag. When set, it releases the bus and then
automatically generates a start condition.
Wait status (during master mode):
Generates a restart condition after wait is canceled.
Cautions concerning set timing
• For master reception:
Cannot be set during transfer. Can be set only at the waiting period when ACKE0
has been set to 0 and slave has been notified of final reception.
• For master transmission: A start condition may not be generated normally during the ACK period.
Therefore, set it during the waiting period.
• Cannot be set at the same time as SPT0
Condition for clearing (STT0 = 0)
Condition for setting (STT0 = 1)
• Cleared by loss in arbitration
• Set by instruction
• Cleared after start condition is generated by master
device
• Cleared by LREL0 = 1
• When IICE0 = 0
• When RESET is input
Note
This flag’s signal is invalid when IICE0 = 0.