NovaScale R620 User Guide
Supplement
Note the following when using ESMPRO Agent.
Dual registration of event logs
At some types of errors, two event logs may be registered for a single occurrence. (However, in the case of ESMPRO
Manager, one log is reported for one occurrence.) Such errors are as follows:
- Temperature error
- Voltage error
- Thermal trip
Maintenance-related Functions
When you want to use maintenance-related functions, contact your maintenance personnel.
CPU Information
If you select [CPU Module]–[CPU] in the FT tree of the data viewer, unknown or incorrect information appears in some
information items.
The CPU information can be viewed by selecting [System]–[CPU] in the [ESMPRO] tree.
Module Diagnostics
When you diagnose a PCI module (IO module), the CPU module of the same side will also be diagnosed. Therefore, the
CPU module also needs to be stopped.
Status during Module Diagnostics
While diagnosing a stopped module, the module is no longer in the duplex mode and the CPU and the memory cannot
be used. However, the status of [CPU] and [DIMM] displayed under [CPU module] in the FT tree on a Data Viewer
becomes “Online” and the status colour becomes green.
Change of Installation States of CPU and PCI (IO) Modules
If you dynamically change the configuration of the CPU or PCI module (IO module) in the relevant system during
review of the server information by using the data viewer, the message prompting you to reconstruct the tree of the data
viewer will appear. If you click the [Yes] button, the tree is reconstructed in the data viewer to reflect the change of the
system configuration on the data viewer. Clicking the [No] button does not cause the tree to be reconstructed in the data
viewer. If so, the information in the data viewer may be different from the current system information because the
change of the system configuration is not reflected on the data viewer.
Status of Logical PCI Slots
Because the I/O hub and display controller on a PCI module (IO module) are logical PCI slot information, PCI module
(IO module) are not influenced by them. Therefore, the “Status” of [PCI slot (ID:0/10/102)] and [PCI slot
(ID:0/10/103)] under [PCI module (ID:0/10)] and the “Status” of [PCI slot (ID:1/11/102)] and [PCI slot(ID:1/11/103)]
under [PCI module (ID:1/11)] in the FT tree on a Data Viewer becomes “Online” and the status colour becomes green.
Impact of Module Status Changes
PCI modules (IO modules), SCSI adapters, SCSI buses, and modules under the SCSI enclosure have impact on each
other. For example, when the “Status” item of a module changes to “fault,” it may be caused by another module’s error.
5-20
Содержание Bull NovaScale R620 Series
Страница 1: ...User s Guide Bull NovaScale R620...
Страница 2: ......
Страница 17: ...NovaScale R620 User Guide Water cooling kit 1 4...
Страница 74: ...NovaScale R620 User Guide 7 Configure the mirror of the extended volume 3 15...
Страница 122: ...NovaScale R620 User Guide Exit Move the cursor onto Exit to display the Exit menu 4 23...
Страница 263: ...Chapter 7 Troubleshooting If the product does not work properly see this chapter before deciding that it is a breakdown...
Страница 345: ...This page is deliberately left empty...
Страница 346: ......