CPU/IO status
LED indications
Description Action
Green
The CPU/IO module is
running successfully.
–
A number of errors that
can be fixed by memory
are occurring.
Although you can continue using the server, it is recommended to
contact your service agent.
Blinking green
The CPU/IO module
handle is not firmly fixed.
Check to see the CPU/IO module is firmly loaded and then fasten
the screws of the handle to fix the handle.
Power supply is off.
-
POST is running.
Wait for a while; the LED will illuminate in green and the mode will
become Duplex shortly after POST.
Not on
A fatal hardware error has
occurred.
Contact your sales agent.
One of the CPU/IO
modules has a problem.
Check the CPU/IO module status LEDs to find the failing module,
and then report your sales agent which LED of the failing module is
blinking.
Detected a fatal
temperature error.
Check if dust is accumulated on internal fans and confirm that the
fan cables are connected firmly. If the LED indication does not
change, contact your sales agent.
Detected a fatal voltage
error.
Contact your sales agent.
Amber
Power supply has a
problem.
Contact your sales agent.
Detected a temperature
error to be warned.
Check if dust is accumulated on internal fans and confirm that the
fan cables are connected firmly. If the LED indication does not
change, contact your sales agent.
Detected a voltage error
to be warned.
Contact your sales agent.
Amber (blinking)
Detected a fan alarm.
Check if dust is accumulated on internal fans, and confirm that the
fan cables are connected firmly. If the LED indication does not
change, contact your sales agent.
2-19
Содержание Bull NovaScale R620 Series
Страница 1: ...User s Guide Bull NovaScale R620...
Страница 2: ......
Страница 17: ...NovaScale R620 User Guide Water cooling kit 1 4...
Страница 74: ...NovaScale R620 User Guide 7 Configure the mirror of the extended volume 3 15...
Страница 122: ...NovaScale R620 User Guide Exit Move the cursor onto Exit to display the Exit menu 4 23...
Страница 263: ...Chapter 7 Troubleshooting If the product does not work properly see this chapter before deciding that it is a breakdown...
Страница 345: ...This page is deliberately left empty...
Страница 346: ......