NovaScale R620 User Guide
10.
After pressing the CPU softly against the socket, place the CPI
socket holder back to its original place.
11.
Return the socket lever back to its original place.
12.
Place the heat sink on the CPU and secure it with 4 screws. Loosely
fasten the screws in the cross-coupling way, and then fasten them tightly.
13.
Check that the heat sink mounted on the CPU is level with the motherboard.
IMPORTANT:
If the heat sink is leaning, remove it and then mount it again. The following are possible causes:
- The CPU has not been installed correctly.
- The screws have not been fastened tight enough.
Do not move the heat sink that has been secured with the screws.
14.
Insert the cable and fix the cooling fan unit.
15.
Install the CPU/IO module referring to page 8-13.
16.
Connect the power cord.
17.
Turn on the power by pressing the POWER switch.