NovaScale R620 User Guide
7-16
Fail to start the OS:
Is there a diskette in the floppy disk drive?
Take out the diskette and restart the server.
Is the EXPRESSBUILDER CD-ROM (or another bootable CD-ROM) in the CD-ROM drive?
Take out the CD-ROM and restart the server.
Is the OS damaged?
Use the recovery process of the OS to attempt to recover the damaged OS.
OS behaviour is unstable:
Have you updated your system?
For update procedure, see the separate volume
“
User
’
s Guide (Setup)
”
.
The system does not operate according to the configured settings of "Automatic Restart" at the
occurrence of error.
The system may or may not restart automatically even if the "Automatic Restart" settings are made at
occurrence of an error is set. If the system does not restart automatically, restart it in manual mode.
The power cannot be turned off while the blue screen of Windows Server 2003 Enterprise Edition is
displayed.
The forced power-off (forced shutdown) procedure is necessary to turn off the power with the blue
screen displayed. Keep pressing the POWER switch for about 4 seconds. Pressing the POWER switch
quickly does not turn off the power in this case.
The server is not found on the network:
Is the LAN cable connected?
Make sure to connect the LAN cable to the network port on the rear of the server. Also make sure to use
the LAN cable that conforms to the network interface standard.
Have the protocol and service already been configured?
Install the distinctive network driver for the server. Make sure that the protocol, such as TCP/IP, and
services are properly specified.
Is the transfer speed correct?
The built-in LAN controller mounted as standard on this server can be used in network with the transfer
speed of 1000 Mbps, 100 Mbps or 10 Mbps. You can change the transfer speed or configure the setting
from OS. However, do not use the
“
Auto Detect
”
function. Fix the setting of the transfer rate to the same
as that of the connected hub. Also, check if the duplex mode is the same as that of the connected hub.
Fix the transfer speed by using Device Manager. Select and right-click the network adapter to change the
transfer speed from the tree on Device Manager, and select [Properties] from the displayed menu. When
the properties window appears, select the [Link] tab, and select the item that matches to the connected
HUB from the list box of [Speed and Duplex]. If you click [OK], configuration selected in [Speed and
Duplex] will be effective.
Icon of drive A is changed to that of removal disk:
Does not cause any problem.
Machine repeats rebooting at startup:
Is CHKDSK executed at machine start-up?
Open the utility of the BIOS setup at rebooting and change the following settings:
(Change BIOS settings)
Change [Server] - [Monitoring Configuration] - [Boot Monitoring] to [Disable].
Содержание Bull NovaScale R620 Series
Страница 1: ...User s Guide Bull NovaScale R620...
Страница 2: ......
Страница 17: ...NovaScale R620 User Guide Water cooling kit 1 4...
Страница 74: ...NovaScale R620 User Guide 7 Configure the mirror of the extended volume 3 15...
Страница 122: ...NovaScale R620 User Guide Exit Move the cursor onto Exit to display the Exit menu 4 23...
Страница 263: ...Chapter 7 Troubleshooting If the product does not work properly see this chapter before deciding that it is a breakdown...
Страница 345: ...This page is deliberately left empty...
Страница 346: ......