![background image](http://html1.mh-extra.com/html/nec/bull-novascale-r620-series/bull-novascale-r620-series_user-manual_3916556217.webp)
NovaScale R620 User Guide
MTBF Information contains the following information:
Item
Description
Type
Monitoring status of MTBF.
Use Threshold: MTBF is calculated at a fault occurrence. The device is
stopped when the calculated value is lower than the
threshold.
Never Restart: Always stops the device at a fault occurrence.
Always Restart: Always restarts the device at a fault occurrence.
Threshold
Threshold of MTBF.
When the threshold is not specified,
“
--
”
is displayed.
Current Current
MTBF
value.
When there is no or few errors,
“
--
”
is displayed because MTBF cannot
be calculated.
Faults
Number of faults
Time of last fault
Time of the last fault.
When there is none, “--” is displayed.
Firmware contains the following information:
Item
Description
Version
Version of the firmware (System BIOS)
Additional Information
Additional information of the firmware (System BIOS)
The following buttons are displayed for CPU Module:
Item
Description
Clear
Clears the MTBF information of the CPU module
Up
Starts the CPU module. When you also start the PCI module of the same
module, start the PCI module before the CPU module.
Down
Stops the CPU module
Firmware
Updates the firmware (System BIOS)
Jump Switch
Switches the board.
Start the IO module and the CPU module of the sopped module
respectively and make modules duplex. Then, stop the other module's
CPU module and IO module respectively.
* Use this function when updating the firmware (BIOS). This function is
available for a module which CPU and PCI (IO) modules are stopped.
Harvest
Collects dump.
Before clicking this button, select one of the methods of to collect dump:
•
Save memory dump of the stopped module.
•
Harvest memory dump of the current system without stopping it.
*Check the result of dumping by an event log. This function cannot be
used if “Complete memory dump” is not set on Windows setting. In such
a case, a dump is not produced even if it is requested. Do not start or
stop the module while producing a dump.
* (1) The execution of each button may take a few minutes. Wait for a while to update the display and check the
module status.
(2) This system performs diagnostics to both CPU module and PCI module on the same board. Execute diagnostics
from a PCI module.
(3)
These operations cannot be performed while collecting dump or updating firmware. Wait until such processing is
finished to perform the operations in the table.
5-43
Содержание Bull NovaScale R620 Series
Страница 1: ...User s Guide Bull NovaScale R620...
Страница 2: ......
Страница 17: ...NovaScale R620 User Guide Water cooling kit 1 4...
Страница 74: ...NovaScale R620 User Guide 7 Configure the mirror of the extended volume 3 15...
Страница 122: ...NovaScale R620 User Guide Exit Move the cursor onto Exit to display the Exit menu 4 23...
Страница 263: ...Chapter 7 Troubleshooting If the product does not work properly see this chapter before deciding that it is a breakdown...
Страница 345: ...This page is deliberately left empty...
Страница 346: ......