NovaScale R620 User Guide
7-10
Error Notification by BEEP
An error message may not be displayed on the display unit even though the POST detected an error. In such a case, the
beep sounds notifies you an error. The error contents are indicated by the combination of beep sound patterns. For
example, beep sounds once, consecutively three times, once, and then once (beep code: 1-3-1-1) indicates DRAM
refresh test error.
The following table lists the meaning of beep codes and measures against them.
Beep code
Meaning
Action
1-2-2-3
ROM checksum error
Contact your sales agent to replace the CPU/IO module
motherboard.
1-1-2-4
ROMEXEC code error
1-3-1-1
DRAM refresh test error
Check the installation of DIMM board.
If the error persists, contact your sales agent to replace the DIMM
or CPU/IO module motherboard.
1-3-1-3
Keyboard controller error
Disconnect the keyboard and connect it back on. If the error
persists, request your sales agent to replace the CPU/IO module
motherboard.
1-3-3-1
Failed to detect memory.
Or, DIMM board type is
incorrect.
1-3-3-2
Initial setting error of the
POST memory manager
1-3-4-1
RAM address error
1-3-4-3
RAM low byte data error
1-4-1-1
RAM high byte data error
Check the installation of DIMM board.
If the error persists, contact your sales agent to replace the DIMM
or CPU/IO module motherboard.
2-2-3-1
Illegal interrupt test error
2-1-2-3
Copyright check error
Contact your sales agent.
Failed to initialize the video
BIOS
Failed to initialize the option
ROM
1-2
Failed to expand the option
ROM
Check the motherboard installation if nothing is displayed on the
display unit. If the error persists, contact your sales agent to replace
the CPU/IO module motherboard.
Check the PCI board installation if the Option ROM of the added
PCI board is not displayed. If the error persists, contact your sales
agent to replace the CPU/IO module motherboard, PCI module
board or added PCI board with new one.
1-5-1-1
FRB3 monitoring timeout
Check the installation of CPU. If the error persists, contact your
sales agent.
1-5-2-2
CPU not implemented error
Check the installation of CPU. If the error persists, contact your
sales agent.
1-5-2-3
CPU configuration error
Check the installation of CPU. If the error persists, contact your
sales agent.
1-5-4-2
1-5-4-4
Power error
Check the installation of power. If the error persists, contact your
sales agent.
Содержание Bull NovaScale R620 Series
Страница 1: ...User s Guide Bull NovaScale R620...
Страница 2: ......
Страница 17: ...NovaScale R620 User Guide Water cooling kit 1 4...
Страница 74: ...NovaScale R620 User Guide 7 Configure the mirror of the extended volume 3 15...
Страница 122: ...NovaScale R620 User Guide Exit Move the cursor onto Exit to display the Exit menu 4 23...
Страница 263: ...Chapter 7 Troubleshooting If the product does not work properly see this chapter before deciding that it is a breakdown...
Страница 345: ...This page is deliberately left empty...
Страница 346: ......