After starting up, FT Status LED do not illunimiate or illunimate amber:
Follow the instructions below:
FT Status LED
Description
Action
Green
CPU module, IO module, SCSI
adapter, FC adapter, and
network adapter are in complete
dual mode.
No action is necessary.
Amber
1. An error occurred in CPU/IO
module or IO module.
2. CPU module
’
s MTBF went
below the threshold value.
Contact your sales agent, since device replacement is
usually required.
Blink in amber
Collecting the dump.
No action is necessary.
Preparing for dual mode.
Wait for a while.
CPU module and/or IO module
and/or SCSI adapter and/or FC
adapter and/or network adapter
are not in dual mode.
1. CPU module: See
“
CPU module is separated
”
and
“
CPU module is not integrated
”
in this chapter.
2. IO module: See
“
IO module is separated
”
and
“
IO
module is not integrated
”
in this chapter.
3. SCSI adapter: Check if IO module is separated or
SCSI adapter on IO module is broken.
4. FC adapter: Check if IO module is separated and if
storage device is connected from both IO modules
with FC cable. Also check if access to one IO
module is restricted in AccessControl of
iStorageManager.
5. Network adapter: Check the dual mode setting.
Also, check if there is any problem in general
network settings or in the connection.
Not illuminate
HAS Fault Service Tolerance
service is not started.
Start the HAS Fault Tolerance service by selecting
[Administrative Tools]
–
[Services].
Command prompt cannot be display full screen:
In NovaScale/ft Server series
,
you cannot switch command prompt to full screen mode. Also, you cannot
execute applications that use command prompt full screen mode. When you attempt to switch to full
screen mode, the message below may appear. Click [OK] and close the window.
<Example message>
Screen display size and actual drawing range do not match:
This may occur when you use application that can change resolution. Close the application. If the screen
condition does not change even after closing the application, go to [Display Properties] - [Settings] tab -
[Screen resolution] and reset the resolution. You must reboot the system for new settings to take effect.
Exclamation mark
“
!
”
appears to
“
VGA Display Controller
”
under the
“
non-Plug and Play device
”
when changed the setting to show hidden devices in menu in the Device Manager:
This has to do with the server specification and there is no effect to the operation. Exclamation mark
“
!
”
appears to
“
VGA Display Controller
”
since OS Standard VGA driver is not activated in the server.
Exclamation mark
“
!
”
appears to
“
Serial
”
under the
“
non-Plug and Play device
”
when changed the
setting to display a non-display device in the menu by using Device Manager:
There is no serial port that is a legacy device in NovaScale/ft Server series. When you install Windows to
a legacy-free server like NovaScale/ft Server series, exclamation mark
“
!
”
may appears to
“
Serial
”
. This
has to do with the OS specification and there is no effect to the operation of the server.
Содержание Bull NovaScale R620 Series
Страница 1: ...User s Guide Bull NovaScale R620...
Страница 2: ......
Страница 17: ...NovaScale R620 User Guide Water cooling kit 1 4...
Страница 74: ...NovaScale R620 User Guide 7 Configure the mirror of the extended volume 3 15...
Страница 122: ...NovaScale R620 User Guide Exit Move the cursor onto Exit to display the Exit menu 4 23...
Страница 263: ...Chapter 7 Troubleshooting If the product does not work properly see this chapter before deciding that it is a breakdown...
Страница 345: ...This page is deliberately left empty...
Страница 346: ......