NovaScale R620 User Guide
FILE CHECK FEATURE OF GeminiEngine Control Software
To make sure that the files that construct the software controlling duplex operation (GeminiEngine Control Software)
are kept properly, the NEC Express5800/ft series has a file check feature. This feature runs at a system startup and when
logging on as the administrator user that set up the system.
This feature is automatically installed by Express Setup.
Checking files
The file check feature of GeminiEngine Control Software is performed at the following two occasions:
z
When starting OS
Checks files as a task that is automatically run at an OS startup. FLVERCHK.EXE is registered as a hidden task in
the task scheduler, and it is set to run at a system startup.
The check result is recorded in event log.
z
When logging on as the user that performed setup of the server (Administrator of the build-in account)
Checks files when logging on as a user that set up the server. A shortcut to FlVerChk.exe is registered in the startup
folder of the user, and files are checked when logging on.
When an invalid update is detected, the check result is displayed on the [GeminiEngine Control Software File
Checker] dialog.
When you log on as a user other than the one that set up the system, the file check feature of GeminiEngine
Control Software does not run. If you want to run the file check feature when logging on, copy the shortcut to
FlVerChk.exe in the startup folder of the user that set up the system (usually, it is located at C:\Documents and
Settings\Administrator\Start Menu\Programs\Startup) to the startup folder of the user to run the file check.
Administrator authority is required for running the file check.
FlVerChk.exe is stored at C:\Program Files\NEC\HAS_SW\VERCHK\BIN\Support. If you cannot access the
startup folder of the user that set up the server, create a shortcut to FlVerChk.exe, and store it in the startup folder
of the user to run the file check.
In those cases, the file check feature is run temporarily and does not reside in the system. Use these settings as they are
in order to detect invalid update of GeminiEngine Control Software at an early stage.
3-36
Содержание Bull NovaScale R620 Series
Страница 1: ...User s Guide Bull NovaScale R620...
Страница 2: ......
Страница 17: ...NovaScale R620 User Guide Water cooling kit 1 4...
Страница 74: ...NovaScale R620 User Guide 7 Configure the mirror of the extended volume 3 15...
Страница 122: ...NovaScale R620 User Guide Exit Move the cursor onto Exit to display the Exit menu 4 23...
Страница 263: ...Chapter 7 Troubleshooting If the product does not work properly see this chapter before deciding that it is a breakdown...
Страница 345: ...This page is deliberately left empty...
Страница 346: ......