NovaScale R620 User Guide
System Operation Setup
The following properties can be set as the operation setup of the whole system.
Quick dump that is harvested at the same time of reboot
If “Enable” is selected for this item, dump is collected as the system reboots when an error occurs in the system.
When “Disable” is selected, dump is collected by the OS standard dump function.
The default value is “Enable.”
IMPORTANT:
To use the quick dump function, refer to “Make Settings for Failure Management” in the User’s Guide (Setup) to
set “Complete memory dump” for the memory dump setting and reboot the system. When the setting is not set to
“Complete memory dump”, the standard memory dump function is performed even if the quick dump setting is
set to “Enable” In addition, the standard memory dump function is used when “Complete memory dump” cannot
be specified because mounted memory exceeds 2 GB.
Auto firmware update
If “Enable” is selected for this item, the BIOS of the new CPU module is updated to the BIOS of the existing CPU
module to match with each other. If “Disable” is selected, the BIOS of the new CPU module is not updated
automatically.
The default value is “Enable.”
Auto module start
If “Enable” is selected for this item, modules will be put into the duplex mode automatically when mounting both
modules and restarting the system. If “Disable” is selected, the modules will not be in the duplex mode.
The default value is "Enable."
Settings can be made in the [System Configuration] window of Server Maintenance Utility.
The table below shows the potential cases in which the system operation setup is changed. Contact your maintenance
personnel for the change of the system operation setup. Setting change will take effect after system reboot. However,
the utility does not indicate that reboot is required.
Quick dump
Auto firmware update
Auto module start
Componen
t
Remote Local
Remote Local
Remote Local
Whole
system
–
Executable if
the system is
operating.
When dump is
acquired by
using the dump
function
normally
installed in OS
at occurrence of
system fault.
–
Executable if the
system is
operating.
When firmware is
updated manually
at insertion of
new module
–
Executable if the
system is
operating.
When firmware is
started manually at
insertion of new
module
Remote: Executable from remote management PC by using ESMPRO Manager
Local:
Executable on local server by using Server Maintenance Utility
–: Not
supported
5-67
Содержание Bull NovaScale R620 Series
Страница 1: ...User s Guide Bull NovaScale R620...
Страница 2: ......
Страница 17: ...NovaScale R620 User Guide Water cooling kit 1 4...
Страница 74: ...NovaScale R620 User Guide 7 Configure the mirror of the extended volume 3 15...
Страница 122: ...NovaScale R620 User Guide Exit Move the cursor onto Exit to display the Exit menu 4 23...
Страница 263: ...Chapter 7 Troubleshooting If the product does not work properly see this chapter before deciding that it is a breakdown...
Страница 345: ...This page is deliberately left empty...
Страница 346: ......