NovaScale R620 User Guide
Removing Hard Disk Drives Which Do Not Have Error
1.
To replace the disk that does not have any error in Slot 0 or Slot 3 for preventive maintenance:
Follow the instructions on the previous pages.
IMPORTANT:
Do not run “Remove Mirror” before removing the hard disk drive.
2.
To replace a disk that is in a slot other than Slot 0 and Slot 3 and does not have any error for preventive
maintenance:
Follow the steps below and remove the disk drive that you are to replace from the management target of Windows,
and then perform the operations described on the previous pages.
1.
Run “Remove Mirror” to make the disk to be replaced in the “Unallocated” status.
2.
From [Computer Management], display [Device Manager] and display items under “Disk drives.”
3.
Find the hard disk to be removed from the disks displayed under “Disk drives” by checking the slot number in
the properties (find the one whose slot number matches the target ID).
In this server, since each disk drive is accessed from both active and standby modules, [Device Manager]
shows each disk as two disks logically. Therefore, remove the two corresponding disks of the disk to be
removed.
3-23
Содержание Bull NovaScale R620 Series
Страница 1: ...User s Guide Bull NovaScale R620...
Страница 2: ......
Страница 17: ...NovaScale R620 User Guide Water cooling kit 1 4...
Страница 74: ...NovaScale R620 User Guide 7 Configure the mirror of the extended volume 3 15...
Страница 122: ...NovaScale R620 User Guide Exit Move the cursor onto Exit to display the Exit menu 4 23...
Страница 263: ...Chapter 7 Troubleshooting If the product does not work properly see this chapter before deciding that it is a breakdown...
Страница 345: ...This page is deliberately left empty...
Страница 346: ......