NovaScale R620 User Guide
7-21
CPU load ratio of SNMP Service (snmp.exe) increases:
While monitoring the server from ESMPRO Manager, the CPU load ratio of SNMP Service on the
ESMPRO Agent side may increase at every monitoring interval (default: 1 minute).
ESMPRO Manager and ESMPRO Agent exchange information through SNMP Service. If the server
status monitoring by ESMPRO Manager is on (default: ON), ESMPRO Manager regularly issues a
request to ESMPRO Agent to get the current status of the server. In response, ESMPRO Agent checks
the status of the server. As a result, the CPU load ratio of SNMP Service increases temporarily.
If you have trouble of terminating a movie player application, turn off the server status monitoring by
ESMPRO Manager or extend the monitoring interval.
SNMP Service caused hang:
SNMP Service has a module called
“
SNMP Extended Agent.
”
This module may be registered when you
install some software that uses SNMP Service. If you start SNMP Service, SNMP Extended Agent is
also loaded at the initialization. However, if the initialization is not completed within a specified period,
SNMP Service will hang. It may take time to complete the initialization due to temporary high load on
the system. In this case, wait for the system load become low enough before restarting SNMP Service.
Pop-up message of esmcmn.exe is displayed when starting the system:
→
The following pop-up message may be displayed when you restart the system which ESMPRO Agent is
installed to and removal drives such as MO and DVD-RAM are mounted on, without closing Windows
Explorer, after displaying the contents of media and removing the media by the software eject (by
right-clicking the DVD drive on Windows Explorer and selecting [Eject]) The message (the drive name)
displayed varies depeneding on the systems.
If the pop-up messages below are displayed, click [Cancel] or [Continue] to close the dialog box. If you
do not close the dialog box, you cannot start the Workstation service and related services, causing unstable
operation of the system. Also, if you restart the system, execute it after terminating the program such as
Windows Explorer which displays a media.
<Example >
Memory dump (debug information) cannot be collected when a failure occurs:
Is there any available storage space on a storage location?
Specify the drive in which there is an available storage space of more than a memory size on the
server plus 12 MB (more than 2048 plus 12 MB if a memory size is more than 2 GB ).
For details, see
“
Set Memory Dump (Debug Information)
”
of
“
Step 12: Set up Failure Management
”
in Chapter 4
“
Windows Setup
”
in the separate User
’
s Guide for setup.
Is [Initial size] of the paging file of the OS partition smaller than [Recommended]?
If a value smaller than the [Recommended] value is set for [Initial Size] of the paging file, accurate
memory dump (debug information) may not be collected. Be sure to create the file in the above size in
the OS partition.
For details, see
“
Set Memory Dump (Debug Information)
”
of
“
Step 12: Set up Failure Management
”
in Chapter 4
“
Windows Setup
”
in the separate User
’
s Guide for setup.
Содержание Bull NovaScale R620 Series
Страница 1: ...User s Guide Bull NovaScale R620...
Страница 2: ......
Страница 17: ...NovaScale R620 User Guide Water cooling kit 1 4...
Страница 74: ...NovaScale R620 User Guide 7 Configure the mirror of the extended volume 3 15...
Страница 122: ...NovaScale R620 User Guide Exit Move the cursor onto Exit to display the Exit menu 4 23...
Страница 263: ...Chapter 7 Troubleshooting If the product does not work properly see this chapter before deciding that it is a breakdown...
Страница 345: ...This page is deliberately left empty...
Страница 346: ......