16 - 36
Chapter 16 Troubleshooting
Classification
of errors
Error
code
Error name
Error
Operation status at error occurrence
906
Outside bias speed
range
• The set value of the basic parameter 1
"Bias speed at start" is outside the setting
range.
• The bias speed exceeds the speed limit.
907
Outside electronic gear
setting range
The set value of the electronic gear is
outside the setting range.
The QD77 READY signal [X0] is not turned
ON.
910
Outside speed limit
value range
• The set value of the basic parameter 2
"Speed limit value" is outside the setting
range.
• The speed limit value is smaller than the
OPR speed.
911
Outside acceleration
time 0 range
The set value of the basic parameter 2
"Acceleration time 0" is outside the setting
range.
912
Outside deceleration
time 0 range
The set value of the basic parameter 2
"Deceleration time 0" is outside the setting
range.
When the PLC READY signal [Y0] is turned
from OFF to ON
: QD77 READY signal [X0] is not
turned ON.
At start
: The system does not operate.
920
Backlash
compensation amount
error
The calculation result of the following
equation is smaller than 0 or larger than
65536.
0
≤
Pr.11
×
Pr.2
Pr.3
×
Pr.4
≤
65535
921
Software stroke limit
upper limit
• In the unit of "degree", the set value of the
detailed parameter 1 "Software stroke
limit upper limit value" is outside the
setting range.
• In a unit other than degree, the software
stroke limit upper limit value is smaller
than the software stroke limit lower limit
value.
922
Software stroke limit
lower limit
• In the unit of "degree", the set value of the
detailed parameter 1 "Software stroke
limit lower limit value" is outside the
setting range.
• In a unit other than degree, the software
stroke limit upper limit value is smaller
than the software stroke limit lower limit
value.
923
Software stroke limit
selection
• The set value of the detailed parameter 1
"Software stroke limit selection" is outside
the setting range.
• In the unit of "degree", "1: Apply software
stroke limit on machine feed value" is set.
Parameter
setting range
errors
924
Software stroke limit
valid/invalid setting
The set value of the detailed parameter 1
"Software stroke limit valid/invalid setting" is
outside the setting range.
The QD77 READY signal [X0] is not turned
ON.
Содержание MELSEC-Q QD77MS
Страница 1: ......
Страница 27: ...A 26 MEMO...
Страница 29: ...MEMO...
Страница 101: ...3 34 Chapter 3 Specifications and Functions MEMO...
Страница 232: ...5 111 Chapter 5 Data Used for Positioning Control MEMO...
Страница 315: ...5 194 Chapter 5 Data Used for Positioning Control MEMO...
Страница 337: ...6 22 Chapter 6 Sequence Program Used for Positioning Control...
Страница 338: ...6 23 Chapter 6 Sequence Program Used for Positioning Control...
Страница 339: ...6 24 Chapter 6 Sequence Program Used for Positioning Control...
Страница 340: ...6 25 Chapter 6 Sequence Program Used for Positioning Control...
Страница 341: ...6 26 Chapter 6 Sequence Program Used for Positioning Control...
Страница 342: ...6 27 Chapter 6 Sequence Program Used for Positioning Control...
Страница 343: ...6 28 Chapter 6 Sequence Program Used for Positioning Control...
Страница 344: ...6 29 Chapter 6 Sequence Program Used for Positioning Control...
Страница 345: ...6 30 Chapter 6 Sequence Program Used for Positioning Control...
Страница 346: ...6 31 Chapter 6 Sequence Program Used for Positioning Control...
Страница 347: ...6 32 Chapter 6 Sequence Program Used for Positioning Control...
Страница 348: ...6 33 Chapter 6 Sequence Program Used for Positioning Control...
Страница 349: ...6 34 Chapter 6 Sequence Program Used for Positioning Control...
Страница 353: ...6 38 Chapter 6 Sequence Program Used for Positioning Control...
Страница 354: ...6 39 Chapter 6 Sequence Program Used for Positioning Control...
Страница 357: ...6 42 Chapter 6 Sequence Program Used for Positioning Control...
Страница 359: ...6 44 Chapter 6 Sequence Program Used for Positioning Control...
Страница 360: ...6 45 Chapter 6 Sequence Program Used for Positioning Control...
Страница 361: ...6 46 Chapter 6 Sequence Program Used for Positioning Control...
Страница 363: ...6 48 Chapter 6 Sequence Program Used for Positioning Control...
Страница 364: ...6 49 Chapter 6 Sequence Program Used for Positioning Control...
Страница 413: ...MEMO...
Страница 433: ...8 20 Chapter 8 OPR Control MEMO...
Страница 458: ...9 25 Chapter 9 Major Positioning Control MEMO...
Страница 593: ...10 30 Chapter 10 High Level Positioning Control MEMO...
Страница 625: ...11 32 Chapter 11 Manual Control MEMO...
Страница 659: ...12 34 Chapter 12 Expansion Control MEMO...
Страница 767: ...13 108 Chapter 13 Control Sub Functions MEMO...
Страница 813: ...14 46 Chapter 14 Common Functions MEMO...
Страница 831: ...15 18 Chapter 15 Dedicated Instructions MEMO...
Страница 846: ...16 15 Chapter 16 Troubleshooting MEMO...
Страница 892: ...16 61 Chapter 16 Troubleshooting MEMO...
Страница 971: ...Appendix 62 Appendices MEMO...
Страница 974: ......
Страница 975: ......