Programming Manual - Basic & Applied Instruction Edition
A Programming Tool Applicability and Version Upgrade History
A-2 Version Upgrade History
Appendix A-2-4 Version upgrade history [FX
3UC
]
→
For the method to look at the manufacturer’s serial number, refer to Appendix A-2-2
Version
Manufacturer’s
serial number
Contents of version upgrade
Ver.1.00
41******
(January, 2004)
First product
Ver.1.20
44******
(April, 2004)
Supports connection of following special analog adapters:
-
FX
3U
-4AD-ADP
-
FX
3U
-4DA-ADP
Ver.1.30
48******
(August, 2004)
•
Supports connection of following special analog adapters:
-
FX
3U
-4AD-PT-ADP
-
FX
3U
-4AD-TC-ADP
•
Supports connection of following special function block:
-
FX
3UC
-4AD
•
Supports following 3 instructions:
-
SCL2 (FNC269), RWER (FNC 294), and INITER (FNC 295)
•
Adds function of following instruction:
-
DVIT (FNC151)
Ver.2.20
55******
(May, 2005)
Supports the functions described as "Ver.2.00 or later" in this manual.
•
Supports following 28 instructions:
ZPUSH(FNC102), ZPOP(FNC103), WSUM(FNC140),WTOB(FNC141),
BTOW(FNC142),UNI(FNC143), DIS(FNC144), SORT2(FNC149), TBL(FNC152),
COMRD(FNC182), DUTY(FNC186), BK+(FNC192), BK-(FNC193),
BKCMP=(FNC194), BKCMP>(FNC195), BKCMP<(FNC196),
BKCMP<>(FNC197), BKCMP<=(FNC198), BKCMP>=(FNC199), STR(FNC200),
VAL(FNC201), INSTR(FNC208), FDEL(FNC210), FINS(FNC211),
DABIN(FNC260), BINDA(FNC261), RBFM(FNC278), WBFM(FNC279)
•
Adds function of following 5 instructions:
SPD(FNC 56), DSZR(FNC150), DVIT(FNC151), ZRN(FNC156), PLSV(FNC157),
HCMOV(FNC189)
•
Supports connection of FREQROL-F700/A700 inverters supporting following 5
instructions:
IVCK (FNC270), IVDR (FNC271), IVRD (FNC272), IVWR (FNC273), and IVBWR
(FNC274)
•
Adds second entry code
(when GX Developer SW8.23Z (Ver. 8.23Z or later) is used).
•
Supports BFM initial value setting function
(when GX Developer SW8.23Z (Ver. 8.23Z or later) is used).
•
Mitigates restriction in write during RUN
(when GX Developer SW8.23Z (Ver. 8.23Z or later) is used).
-
Number of steps which can be changed by one-time write during RUN is
changed.
127 steps
→
256 steps
-
Handling of circuit blocks which can be changed by one-time write during RUN
is changed.
Program of continuous circuit blocks having 127 steps or less
→
Program of circuit blocks having 256 steps or less in total