765
FX
3U
/FX
3UC
Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
34 SFC Program and Step Ladder
34.2 Step Ladder
31
FN
C
275-FN
C
279
Da
ta
Tr
ans
fe
r 3
32
FN
C
280
-F
N
C
28
9
H
igh Speed
Pr
oces
si
ng 2
33
FN
C
290-FN
C
299
Ext
ensi
on Fi
le
R
egi
st
er
34
SF
C
•S
T
L
Pr
o
g
ra
m
m
in
g
35
In
te
rru
p
t
Funct
ion
36
Sp
e
cia
l De
vic
e
37
E
rro
r C
o
d
e
A
V
e
rs
ion U
p
In
fo
rm
a
tio
n
B
Ex
ec
ut
ion Ti
m
e
s
C
Appl
ic
ab
le
In
st
ru
ct
ion Li
st
34.2
Step Ladder
34.2.1
Outline
In programs using step ladder instructions, a state relay State S is assigned to each process based on
machine operations, and sequences of input condition and output control are programmed as circuits
connected to contacts (STL contacts) of state relays in the same way as SFC programs.
The concept of program creation and the types and operations of state relays are the same as for SFC
programs. However, because the contents can be expressed in the ladder format, step ladder programs can
be handled as familiar relay ladder charts even though the actual contents are the same as those of SFC
programs.
In step ladder programs, the list format is also available.
SFC programs and step ladder programs can be converted each other if they are programmed in the same
rules respectively.
This paragraph explains the expressions and cautions of step ladder programs in comparison with SFC
programs, and the input order in the list format.
34.2.2
Explanation of function and operation
In a step ladder program, a state relay State S is regarded as one control process, and a sequence of input
condition and output control are programmed in a state relay.
Because the preceding process is not performed any more when the program execution proceeds to the next
process, a machine can be controlled using simple sequences for each process.
Operation of step ladder instructions
In a step ladder program, each process performed by the machine is expressed by a state relay.
A state relay consists of a drive coil and contact (STL contact) in the same way as other relays.
Use SET or OUT instruction to drive a coil, and use STL instruction for a contact.
• When a state relay turns ON, a connected circuit (internal circuit) is activated by way of an STL contact.
When a state relay turns OFF, a connected internal circuit is deactivated by way of an STL contact.
After one operation cycle, non-driving of an instruction (jump status) is not available.
• When a condition (transfer condition) provided between state relays is satisfied, the next state relay turns
ON, and the state relay which has been ON so far turns OFF (transfer operation).
In the state relay ON status transfer process, the both state relays are ON only instantaneously (during one
operation cycle).
In the next operation cycle after the ON status was transferred, the former state is reset to OFF.
• One state relay number can be used only once.
*1.
In the next operation cycle after the ON status was transferred from a former state relay to a next state
relay, the former state relay turns OFF.
*2.
An output coil can be used again in different state relays.
STL
S31
Y030
X001
SET
Y31
SET
S32
Y030
Y032
X002
SET
S33
*2
*2
Process of
S32
Process of
S31
STL
S32
When X001 turns ON,
S32 turns ON and S31
is automatically reset
*1
.
STL
S31
Y030
X001
SET
Y31
SET
S32
Y030
Y032
X002
SET
S33
STL
S32
Y31 programmed in
SET instruction remains
ON even if S31 is reset.
Activated