584
FX
3U
/FX
3UC
Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
24 Others – FNC181 to FNC189
24.5 FNC189 – HCMOV / High Speed Counter Move
2. Program example 2
In the program example shown below, the current value of C235 is transferred to D201 and D200, and the
current value of C235 is cleared when X001 turns ON from OFF.
*1.
K0: The current value of the high speed counter is not cleared when DHCMOV instruction is executed.
K1: The current value of the high speed counter is cleared when DHCMOV instruction is executed.
M8394
D200
K1
*1
FNC189
DHCMOV
C235
IRET
0
I101
EI
FEND
When X000 turns ON from OFF, the
interrupt program from I101 to IRET is
executed.
The current value of C235 is
transferred to D201 and D200.
(The current value of C235 is cleared
to “0”.)