369
FX
3U
/FX
3UC
Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
14 Handy Instruction – FNC 60 to FNC 69
14.1 FNC 60 – IST / Initial State
11
FN
C30-
FN
C39
R
o
ta
tion and
Sh
ift
12
FNC
4
0
-FNC49
D
a
ta
Op
e
ra
tio
n
13
FNC5
0
-FNC5
9
H
igh Speed
Pr
ocessi
ng
14
FM
C6
0
-F
NC6
9
H
and
y
In
st
ru
cti
o
n
15
FNC7
0
-FNC7
9
Ex
te
rn
a
l F
X
I
/O
D
evi
ce
16
FNC8
0
-FNC8
9
Ext
e
rnal
FX
D
evi
ce
17
F
N
C1
00
-F
NC
10
9
Da
ta
Tr
ansf
e
r 2
18
FN
C
110-FN
C
13
9
Fl
oat
ing P
o
in
t
19
FN
C
140-FN
C
149
Da
ta
O
per
at
io
n
2
20
FN
C
15
0-F
N
C
159
P
o
si
tioni
ng
C
ont
ro
l
3. Assignment of mode selection inputs
For using IST instruction, it is necessary to assign inputs having consecutive device numbers as shown below
for mode inputs.
When using non-consecutive inputs or omitting some modes, change the layout by using an auxiliary relay as
the head input for mode specification as shown in the figure below.
- X020: Individual operation mode
- X021: Zero return operation mode
- X022: Stepping operation mode
- X023: Cycle operation mode
- X024: Continuous operation
- X025: Zero return start
- X026: Automatic mode start
- X027: Stop
In this example, M0 is used as the head input for mode specification.
X030
M 0
Individual
operation mode
X035
M 1
Zero return
operation mode
X033
M 2
Stepping
operation mode
X040
M 3
Cycle operation
mode
X032
M 4
Continuous
operation
X034
M 5
Zero return
start
X026
M 6
Automatic
mode start
X041
M 7
Stop
M 0
Does not
operate
X030
M 1
Zero return
operation mode
M 2
Does not
operate
M 3
X031
M 4
Continuous
operation
X032
M 5
Zero return
start
M 6
Automatic
mode start
X033
M 7
Stop
M8000
RUN monitor
M8000
M 0
X030
M 1
M 2
M 3
X031
M 4
Continuous
operation
X032
M 5
M 6
Automatic
mode start
X033
M 7
Stop
M8000
M8000
Individual
operation mode
When inputs do not have
consecutive device numbers
Example:
X030: Individual operation mode
X035: Zero return operation mode
X033: Stepping operation mode
X040: Cycle operation mode
X032: Continuous operation mode
X034: Zero return start
X026: Automatic mode start
X041: Stop
When only the continuous
operation mode and zero return
operation mode are used
Example:
X030: Zero return operation mode
X031: Continuous operation mode
X032: Automatic mode start zero
return start
X033: Stop
When only the continuous
operation mode and individual
operation mode are used
Example:
X030: Individual operation mode
X031: Continuous operation mode
X032: Automatic mode start
X033: Stop
Does not
operate
M8000
RUN
monitor
FNC 60
IST
M 0
S 20
S 29
Содержание FX3U Series
Страница 1: ...PROGRAMMING MANUAL Basic Applied Instructions Edition FX3U FX3UC SERIES PROGRAMMABLE CONTROLLERS ...
Страница 2: ......
Страница 889: ......