Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
27 Data Operation 3 – FNC210 to FNC219
27.3 FNC212 – POP / Shift Last Data Read [LIFO Control]
Program example
Among values stored in D20 input first to D101 to D106, the last value input is stored to D10, and “1” is
subtracted from the number of stored data (pointer D100) every time X000 turns ON.
When the first-in data are as shown in the table below
Pointer
D100
K3
Data
D101
H1234
D102
H5678
D103
HABCD
D104
H0000
D105
H0000
D106
H0000
FNC 38
SFWR
D20
K7
END
D100
FNC212
POP
D100
K7
D10
X000
First-in command
Last-in read command
D20
D106
D105
D104
D103
D102
D101
D100
H0000
H0000
H0000
HABCD
H5678
H1234
K3
First-in command
D100:
K2
→
K3
D100:
K1
→
K2
D100:
K0
→
K1
D106
D105
D104
D103
D102
D101
D100
H0000
H0000
H0000
HABCD
H5678
H1234
K3
→
K2
Do not change
D10
HABCD
Last-in read command
X000: OFF
→
ON