822
FX
3U
/FX
3UC
Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
36 Operation of Special Devices (M8000 -, D8000 -)
36.1 Special Device List (M8000 -, D8000 -)
Advanced Function
[D]8160
Not used
–
–
–
–
–
–
–
–
[D]8161
–
–
–
–
–
–
–
–
[D]8162
–
–
–
–
–
–
–
–
[D]8163
–
–
–
–
–
–
–
–
D 8164
FROM (FNC 78), TO (FNC 79) instructions:
Specification of transfer points
–
–
M8164
–
–
3
*1
–
3
[D]8165
Not used
–
–
–
–
–
–
–
–
[D]8166
–
–
–
–
–
–
–
–
[D]8167
–
–
–
–
–
–
–
–
[D]8168
–
–
–
–
–
–
–
–
[D]8169
Access restriction status by 2nd keyword
3
3
*1
–
–
–
–
–
–
*1.
Available in Ver. 2.00 or later.
*2.
The accessibility is restricted depending on the keyword setting status.
N:N Network (setting) (Refer to Data Communication Edition for details.)
[D]8170
Not used
–
–
–
–
–
–
–
–
[D]8171
–
–
–
–
–
–
–
–
[D]8172
–
–
–
–
–
–
–
–
[D]8173
Station number
3
3
–
3
3
3
*3
3
3
[D]8174
Total number of slave stations
3
3
–
3
3
3
*3
3
3
[D]8175
Refresh range
3
3
–
3
3
3
*3
3
3
D 8176
Station number setting
3
3
M8038
3
3
3
*3
3
3
D 8177
Total slave station number setting
3
3
3
3
3
*3
3
3
D 8178
Refresh range setting
3
3
3
3
3
*3
3
3
D 8179
Retry count setting
3
3
3
3
3
*3
3
3
D 8180
Comms time-out setting
3
3
3
3
3
*3
3
3
[D]8181
Not used
–
–
–
–
–
–
–
–
*3.
Available in Ver. 2.00 or later.
Number and name
Content of register
Applicable model
FX
3U
FX
3UC
Correspond-
ing special
device
FX
1S
FX
1N
FX
2N
FX
1NC
FX
2NC
Present
value
Access
restriction
status
Program
Monitor-
ing
Present
value
change
Read Write
H0000
2nd keyword is
not set.
3
*2
3
*2
3
*2
3
*2
H0010 Write protection
3
–
3
3
H0011
Read / write
protection
–
–
3
3
H0012
All online
operation
protection
–
–
–
–
H0020 Keyword cancel
3
3
3
3
Содержание FX3U Series
Страница 1: ...PROGRAMMING MANUAL Basic Applied Instructions Edition FX3U FX3UC SERIES PROGRAMMABLE CONTROLLERS ...
Страница 2: ......
Страница 889: ......