837
FX
3U
/FX
3UC
Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
36 Operation of Special Devices (M8000 -, D8000 -)
36.2 Supplement of Special Devices (M8000 - and D8000 -)
31
FN
C
275-FN
C
279
Da
ta
Tr
ans
fe
r 3
32
FN
C
280
-F
N
C
28
9
H
igh Speed
Pr
oces
si
ng 2
33
FN
C
290-FN
C
299
Ext
ensi
on Fi
le
R
egi
st
er
34
SF
C
•S
T
L
Pr
o
g
ra
m
m
in
g
35
In
te
rru
p
t
Funct
ion
36
Sp
e
cia
l De
vic
e
37
E
rro
r C
o
d
e
A
V
e
rs
ion U
p
In
fo
rm
a
tio
n
B
Ex
ec
ut
ion Ti
m
e
s
C
Appl
ic
ab
le
In
st
ru
ct
ion Li
st
36.2.10 Battery [BATT (BAT)] LED OFF command [M8030]
1. Batteryless operation
When M8030 is set to ON, the battery LED does not turn ON even if the voltage in the battery for memory
backup becomes low.
When the indication of "battery voltage low error" is not required or when the battery is removed, set M8030 to
ON.
When the batteryless operation is required, however, do not use M8030 but refer to "2. Parameter setting in
peripheral equipment" below.
2. Parameter setting in peripheral equipment
Specify "batteryless operation" mode in the parameter settings.
1) When the batteryless operation option is specified
When "batteryless mode" is specified, the control to turn OFF the BATT (BAT) LED and initialization of
the latch area for the devices shown below are automatically executed by the PLC system.
- Auxiliary relay (M)
- Counter (C)
- State relay (S)
- Data register (D)
- Timer (T)
- Extension data register (R)
2) Applicable programming tool
Some programming tool versions do not support "batteryless mode." In such versions, input a sequence
program to enable the batteryless operation as explained below.
3. Conditions for batteryless operation
1) An FLROM (optional memory cassette) for program memory is installed so that programs are not erased.
2) The latch (battery backed) devices such as auxiliary relays and data registers are not used for control.
3) The sampling trace function is not used.
4) The real time clock function is not used.
4. Example program for batteryless mode
When a parameter setting for "batteryless mode" is not available, create the sequence program shown below.
• Example program for clearing the memory backup area
{when the latch (battery backed) ranges in the parameter settings are set to their initial values.}
*1.
The device number is the default number of the latch (battery backed) device range limits in the
parameter settings.
If the latch (battery backed) device numbers in the parameter settings are changed to other values,
change the device numbers here in accordance with the changed latch ranges.
M8000
RUN monitor
FNC 40
ZRST
M500
*1
M7679
M8002
Initial pulse
Auxiliary relay
S500
*1
S4095
State relay
T246
T255
Timer
C100
*1
C199
*1
C220
*1
C255
*1
32 bit counter
D200
*1
D7999
Data register
M8030 BATT(BAT) LED turns OFF.
16 bit counter
FNC 40
ZRST
FNC 40
ZRST
FNC 40
ZRST
FNC 40
ZRST
FNC 40
ZRST
R0
R32767
FNC 40
ZRST
or
M8000
RUN monitor
M8002
Initial pulse
M8030 BATT(BAT) LED
turns OFF.
M8032 The latch areas
are cleared.