634
FX
3U
/FX
3UC
Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
27 Data Operation 3 – FNC210 to FNC219
27.2 FNC211 – FINS / Inserting Data to Tables
27.2
FNC211 – FINS / Inserting Data to Tables
Outline
This instruction inserts data into an arbitrary position in a data table.
1. Instruction format
2. Set data
3. Applicable devices
Explanation of function and operation
1. 16-bit operation (FINS and FINSP)
16-bit data
is inserted in "n"th position in a data table (stored in
and later).
"n"th data and later in the data table are shifted backward one by one, and the number of stored data is added
by "1".
Caution
• The device range used in a data table should be controlled by the user.
The data table has
data starting from the next device (
+1) after
indicating the number of
stored data.
→
Refer to the program example.
Operand Type
Description
Data Type
Device number storing inserted data
16-bit binary
Head device number in data table
n
Data insertion position in table
Oper-
and
Type
Bit Devices
Word Devices
Others
System User
Digit Specification
System User
Special
Unit
Index
Con-
stant
Real
Number
Charac-
ter String
Pointer
X Y M T C S D
.b KnX KnY KnM KnS
T
C
D
R U
\G
V
Z Modify K
H
E
"
"
P
3 3 3 3
3
3 3
3 3 3 3
3
n
3 3
3 3
Mnemonic
Operation Condition
16-bit Instruction
7 steps
FINS
FINSP
Mnemonic
Operation Condition
Continuous
Operation
Pulse (Single)
Operation
32-bit Instruction
⎯
⎯
P
FNC 211
FINS
S
D
S
D
S
D
Command
input
FNC211
FINSP
S
D
n
Data table
D
1234
-123
3
5432
0
0
...
0
...
Data table
range
Device range used in
data table
Data table
D
4444
1234
4
5432
-123
0
...
4444
...
+1
S
Data table
range
When "n" is "2"
0
Number of
stored data
+0
+2
+3
+4
+1
+5
+0
+2
+3
+4
+1
+5
D
D
D
Содержание FX3U Series
Страница 1: ...PROGRAMMING MANUAL Basic Applied Instructions Edition FX3U FX3UC SERIES PROGRAMMABLE CONTROLLERS ...
Страница 2: ......
Страница 889: ......