353
FX
3U
/FX
3UC
Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
13 High Speed Processing – FNC 50 to FNC 59
13.8 FNC 57 – PLSY / Pulse Y Output
11
FN
C30-
FN
C39
R
o
ta
tion and
Sh
ift
12
FNC
4
0
-FNC49
D
a
ta
Op
e
ra
tio
n
13
FNC5
0
-FNC5
9
H
igh Speed
Pr
ocessi
ng
14
FM
C6
0
-F
NC6
9
H
and
y
In
st
ru
cti
o
n
15
FNC7
0
-FNC7
9
Ex
te
rn
a
l F
X
I
/O
D
evi
ce
16
FNC8
0
-FNC8
9
Ext
e
rnal
FX
D
evi
ce
17
F
N
C1
00
-F
NC
10
9
Da
ta
Tr
ansf
e
r 2
18
FN
C
110-FN
C
13
9
Fl
oat
ing P
o
in
t
19
FN
C
140-FN
C
149
Da
ta
O
per
at
io
n
2
20
FN
C
15
0-F
N
C
159
P
o
si
tioni
ng
C
ont
ro
l
4. Handling of pulse output terminals in the FX
3UC
-32MT-LT
The outputs Y000 and Y001 are the high
speed response type.
When using a pulse output instruction or
positioning instruction, adjust the load current
of the open collector transistor output to
about 10 to 100 mA (5 to 24V DC).
When the load is smaller, connect a dummy
resistor in parallel to the outside of a used
output terminal (Y000 or Y001) as shown in
the circuit diagram below so that the
specified current shown above flows in the
output transistor.
5. Cautions on using special high speed output adapters
1) Outputs of special high speed output adapters work as differential line drivers.
2) Set the pulse output type setting switch in a special high speed output adapter to "pulse chain + direction"
(PLS
x
DIR) side.
If the switch is set to "forward rotation pulse chain, reverse rotation pulse chain" (FP
x
RP) side, normal
operations are disabled because the pulse output destination switches depending on the PLC output
status as shown in the table below.
3) Set the pulse output type setting switch while PLC is stopped or while the power is OFF.
Do not manipulate the pulse output form setting switch while pulses are being output.
4) When special high speed output adapters are connected, the same output numbers in the main unit are
assigned as shown in the table below.
Use only an output terminal. Do not perform wiring to the unused output terminals.
Outputs in special high speed output adapters and the main unit operate as shown below.
Assignment of output numbers in special high speed output adapter
Output operation
Pulse output
destination
Output giving
effect on operation
Operation
=
Y000
Y004
While Y004 is ON in PLC, pulses are output from Y000 in high speed output
adapter.
While Y004 is OFF in PLC, pulses are output from Y004 in high speed output
adapter.
=
Y001
Y005
While Y005 is ON in PLC, pulses are output from Y001 in high speed output
adapter.
While Y005 is OFF in PLC, pulses are output from Y005 in high speed output
adapter.
Setting status of output
form setting switch
Signal name
Setting name in each
positioning instruction
Output number
1st unit
2nd unit
1st axis 2nd axis 3rd axis 4th axis
Set to "FP
x
RP" side
Forward rotation
pulse chain (FP)
Pulse output destination
Y000
Y001
Y002
Y003
Reverse rotation
pulse chain (RP)
Rotation direction signal
Y004
Y005
Y006
Y007
Set to "PLS
x
DIR" side
Pulse chain
Pulse output destination
Y000
Y001
Y002
Y003
Direction
Rotation direction signal
Y004
Y005
Y006
Y007
Output operation
Relay output type main unit
Corresponding output remains ON (and the LED remains ON also) while the
instruction is executed.
Special high speed output adapter
Outputs turn ON and OFF normally.
Item
Description
Operating voltage range
5 to 24V DC
Operating current range
10 to 100 mA
Output frequency
100 kHz or less
External
power
supply
Equipment
load
resistor
Dummy
resistor
Y000 or
Y001
COM1
PLC
(transistor output)
[sink output]
Input circuit
D
D
Содержание FX3U Series
Страница 1: ...PROGRAMMING MANUAL Basic Applied Instructions Edition FX3U FX3UC SERIES PROGRAMMABLE CONTROLLERS ...
Страница 2: ......
Страница 889: ......