465
FX
3U
/FX
3UC
Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
18 Floating Point – FNC110 to FNC139
18.4 FNC116 – ESTR / Floating Point to Character String Conversion
11
FN
C30-
FN
C39
R
o
ta
tion and
Sh
ift
12
FNC
4
0
-FNC49
D
a
ta
Op
e
ra
tio
n
13
FNC5
0
-FNC5
9
H
igh Speed
Pr
ocessi
ng
14
FM
C6
0
-F
NC6
9
H
and
y
In
st
ru
cti
o
n
15
FNC7
0
-FNC7
9
Ex
te
rn
a
l F
X
I
/O
D
evi
ce
16
FNC8
0
-FNC8
9
Ext
e
rnal
FX
D
evi
ce
17
F
N
C1
00
-F
NC
10
9
Da
ta
Tr
ansf
e
r 2
18
FN
C
110-FN
C
13
9
Fl
oat
ing P
o
in
t
19
FN
C
140-FN
C
149
Da
ta
O
per
at
io
n
2
20
FN
C
15
0-F
N
C
159
P
o
si
tioni
ng
C
ont
ro
l
18.4
FNC116 – ESTR / Floating Point to Character String Conversion
Outline
This instruction converts binary floating point data into a character string (ASCII codes) having a specified
number of digits.
On the other hand, STR (FNC200) instruction converts binary data into a character string (ASCII codes).
→
For a character string, refer to Section 5.3.
→
For handling of floating point, refer to Subsection 5.1.3.
→
For STR (FNC200) instruction, refer to Section 26.1.
1. Instruction format
2. Set data
3. Applicable devices
Explanation of function and operation
1. 32-bit operation (DESTR and DESTRP)
The contents (binary floating point data) of [
+1,
] are converted into a character string according
to the contents specified by
,
+1 and
+2, and then stored to devices
and later. A real
number can be directly specified as
.
• The data after conversion varies depending on the display specification stored in
.
Operand Type
Description
Data Type
Binary floating point data to be converted or device storing data
Real number (binary)
Head device number storing the display specification of a numeric value to be
converted
32-bit binary
Head device number storing converted character string
Character string
Oper-
and
Type
Bit Devices
Word Devices
Others
System User
Digit Specification
System User
Special
Unit
Index
Con-
stant
Real
Number
Charac-
ter String
Pointer
X Y M T C S D
.b KnX KnY KnM KnS
T
C
D
R U
\G
V
Z Modify K
H
E
"
"
P
3 3
3
3
3
3
3
3
3
3 3 3 3
3
3
3
3
3
3 3 3 3
3
3
−
−
Mnemonic
Operation Condition
16-bit Instruction
DESTR
DESTRP
Mnemonic
Operation Condition
32-bit Instruction
13 steps
Continuous
Operation
Pulse (Single)
Operation
P
FNC 116
ESTR
D
S
1
S
2
D
S
1
S
2
D
S
1
S
1
S
2
S
2
S
2
D
S
1
Command
input
FNC116
DESTR
S
1
S
2
D
S
2
0: Decimal point
format
1: Exponent
format
Total number of
digits
Number of digits
of decimal part
2 to 24 can be set.
The data after conversion varies
depending on the display
specification stored in .
+2
+1
S
2
S
2
S
2
S
2
Содержание FX3U Series
Страница 1: ...PROGRAMMING MANUAL Basic Applied Instructions Edition FX3U FX3UC SERIES PROGRAMMABLE CONTROLLERS ...
Страница 2: ......
Страница 889: ......