813
FX
3U
/FX
3UC
Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
36 Operation of Special Devices (M8000 -, D8000 -)
36.1 Special Device List (M8000 -, D8000 -)
31
FN
C
275-FN
C
279
Da
ta
Tr
ans
fe
r 3
32
FN
C
280
-F
N
C
28
9
H
igh Speed
Pr
oces
si
ng 2
33
FN
C
290-FN
C
299
Ext
ensi
on Fi
le
R
egi
st
er
34
SF
C
•S
T
L
Pr
o
g
ra
m
m
in
g
35
In
te
rru
p
t
Funct
ion
36
Sp
e
cia
l De
vic
e
37
E
rro
r C
o
d
e
A
V
e
rs
ion U
p
In
fo
rm
a
tio
n
B
Ex
ec
ut
ion Ti
m
e
s
C
Appl
ic
ab
le
In
st
ru
ct
ion Li
st
RS2 (FNC 87) [ch1] (Refer to Data Communication Edition for details.)
[M]8400
Not used
–
–
–
–
–
–
–
–
[M]8401
*1
RS2 (FNC 87) [ch1] Send wait flag
3
3
–
–
–
–
–
–
M 8402
*1
RS2 (FNC 87) [ch1] Send request
3
3
D8402
–
–
–
–
–
M 8403
*1
RS2 (FNC 87) [ch1] Receive complete flag
3
3
D8403
–
–
–
–
–
[M]8404
RS2 (FNC 87) [ch1] Carrier detection flag
3
3
–
–
–
–
–
–
[M]8405
Not used
–
–
–
–
–
–
–
–
[M]8406
–
–
–
–
–
–
–
–
[M]8407
–
–
–
–
–
–
–
–
[M]8408
–
–
–
–
–
–
–
–
M 8409
RS2 (FNC 87) [ch1] Time-out check flag
3
3
–
–
–
–
–
–
*1.
Cleared when PLC switches from RUN to STOP or when RS2 instruction [ch1] is OFF.
RS2 (FNC 87) [ch2] and Computer Link [ch2] (Refer to Data Communication Edition for details.)
[M]8410 to [M]8420
Not used
–
–
–
–
–
–
–
–
[M]8421
*2
RS2 (FNC 87) [ch2] Send wait flag
3
3
–
–
–
–
–
–
M 8422
*2
RS2 (FNC 87) [ch2] Send request
3
3
D8422
–
–
–
–
–
M 8423
*2
RS2 (FNC 87) [ch2] Receive complete flag
3
3
D8423
–
–
–
–
–
[M]8424
RS2 (FNC 87) [ch2] Carrier detection flag
3
3
–
–
–
–
–
–
[M]8425
Not used
–
–
–
–
–
–
–
–
[M]8426
Computer link [ch2] Global ON
3
3
D8427
D8428
D8429
–
–
–
–
–
[M]8427
Computer link [ch2] On-demand send processing
3
3
–
–
–
–
–
M 8428
Computer link [ch2] On-demand error flag
3
3
–
–
–
–
–
M 8429
Computer link [ch2] On-demand Word/Byte changeover
RS2 (FNC 87) [ch2] Time-out check flag
3
3
–
–
–
–
–
*2.
Cleared when PLC switches from RUN to STOP or when RS2 instruction [ch2] is OFF.
Error Detection (Refer to Chapter 37 for details.)
[M]8430 to [M]8437
Not used
–
–
–
–
–
–
–
–
M 8438
Serial communication error 2 [ch2]
3
3
D8438
–
–
–
–
–
[M]8439 to [M]8448
Not used
–
–
–
[M]8449
Special block error flag
3
3
*3
D8449
[M]8450 to [M]8459
Not used
–
–
–
–
–
–
–
–
*3.
Available in Ver. 2.00 or later.
Positioning [FX
3U
and FX
3UC
PLCs] (Refer to Positioning Control Edition for details.)
M 8460
DVIT (FNC151) instruction [Y000]
User interrupt input command
3
3
*4
D8336
–
–
–
–
–
M 8461
DVIT (FNC151) instruction [Y001]
User interrupt input command
3
3
*4
D8336
–
–
–
–
–
M 8462
DVIT (FNC151) instruction [Y002]
User interrupt input command
3
3
*4
D8336
–
–
–
–
–
M 8463
DVIT (FNC151) instruction [Y003]
User interrupt input command
3
*5
–
D8336
–
–
–
–
–
M 8464
DSZR (FNC150), ZRN (FNC156) instructions [Y000]
Clear signal device specification function enabled
3
3
*4
D8464
–
–
–
–
–
M 8465
DSZR (FNC150), ZRN (FNC156) instructions [Y001]
Clear signal device specification function enabled
3
3
*4
D8465
–
–
–
–
–
M 8466
DSZR (FNC150), ZRN (FNC156) instructions [Y002]
Clear signal device specification function enabled
3
3
*4
D8466
–
–
–
–
–
M 8467
DSZR (FNC150), ZRN (FNC156) instructions [Y003]
Clear signal device specification function enabled
3
*5
–
D8467
–
–
–
–
–
[M]8468 to [M]8511
Not used
–
–
–
–
–
–
–
–
*4.
Available in Ver. 2.00 or later.
*5.
Available only when two FX
3U
-2HSY-ADP adapters are connected to an FX
3U
PLC.
Number and name
Operation and function
Applicable model
FX
3U
FX
3UC
Correspond-
ing special
device
FX
1S
FX
1N
FX
2N
FX
1NC
FX
2NC
Содержание FX3U Series
Страница 1: ...PROGRAMMING MANUAL Basic Applied Instructions Edition FX3U FX3UC SERIES PROGRAMMABLE CONTROLLERS ...
Страница 2: ......