11
FX
3U
/FX
3UC
Series Programmable Controllers
Programming Manual - Basic & Applied Instructions Edition
Table of Contents
27. Data Operation 3 – FNC210 to FNC219
27.1 FNC210 – FDEL / Deleting Data from Tables........................................................................... 632
27.2 FNC211 – FINS / Inserting Data to Tables ............................................................................... 634
27.3 FNC212 – POP / Shift Last Data Read [LIFO Control] ............................................................. 636
27.4 FNC213 – SFR / Bit Shift Right with Carry................................................................................ 639
27.5 FNC214 – SFL / Bit Shift Left with Carry................................................................................... 641
28. Data Comparison – FNC220 to FNC249
28.1 FNC224~230 – LD =, >, <, <>, <=, >= / Data Comparison ....................................................... 645
28.2 FNC232~238 – AND=, >, <, < >, <=, >= / Data Comparison .................................................... 648
28.3 FNC240~246 – OR=, >, <, < >, <=, >= / Data Comparison ...................................................... 651
29. Data Table Operation – FNC250 to FNC269
29.1 FNC256 – LIMIT / Limit Control ................................................................................................ 655
29.2 FNC257 – BAND / Dead Band Control ..................................................................................... 659
29.3 FNC258 – ZONE / Zone Control ............................................................................................... 662
29.4 FNC259 – SCL / Scaling (Coordinate by Point Data) ............................................................... 665
29.5 FNC260 – DABIN / Decimal ASCII to BIN Conversion ............................................................. 670
29.6 FNC261 – BINDA / BIN to Decimal ASCII Conversion ............................................................. 673
29.7 FNC269 – SCL2 / Scaling 2 (Coordinate by X/Y Data)............................................................. 676
30. External Device Communication
(Inverter Communication) – FNC270 to FNC274
30.1 FNC270 – IVCK / Inverter Status Check................................................................................... 682
30.2 FNC271 – IVDR / Inverter Drive................................................................................................ 684
30.3 FNC272 – IVRD / Inverter Parameter Read.............................................................................. 686
30.4 FNC273 – IVWR / Inverter Parameter Write ............................................................................. 688
30.5 FNC274 – IVBWR / Inverter Parameter Block Write................................................................. 690
31. Data Transfer 3 – FNC275 to FNC279
31.1.1 Common items between RBFM (FNC278) instruction and WBFM (FNC279) instruction ......... 696
32. High Speed Processing 2 – FNC280 to FNC289
33. Extension File Register Control – FNC290 to FNC299
33.1 FNC290 – LOADR / Load From ER .......................................................................................... 708
33.2 FNC291 – SAVER / Save to ER ............................................................................................... 710
33.3 FNC292 – INITR / Initialize R and ER....................................................................................... 718
33.4 FNC293 – LOGR / Logging R and ER ...................................................................................... 721
33.5 FNC294 – RWER / Rewrite to ER............................................................................................. 726
33.6 FNC295 – INITER / Initialize ER ............................................................................................... 730
Содержание FX3U Series
Страница 1: ...PROGRAMMING MANUAL Basic Applied Instructions Edition FX3U FX3UC SERIES PROGRAMMABLE CONTROLLERS ...
Страница 2: ......
Страница 889: ......