1. TROUBLESHOOTING FOR SERVO AMPLIFIER (DRIVE UNIT)
1 - 84
Alarm No.: 84
Name: Network module initialization error
Alarm content
The network module is not connected.
An error occurred at initialization of the network module.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
84.2 Network
module
initialization
error 1
(1) The network module
was disconnected.
Check if the network
module is connected
correctly.
It is not connected
correctly.
Connect it correctly. [Other]
It is connected
correctly.
Check (2).
(2) A network module,
which is not compatible
with the servo amplifier,
has been connected.
Check if the network
module is compatible
with the servo
amplifier.
It is not compatible. Replace with a
network module
compatible with the
servo amplifier.
It is compatible.
Check (3).
(3) A network cable was
disconnected.
Check if the network
cable is connected
correctly.
It is not connected.
Connect it correctly.
It is connected.
Check (4).
(4) The wiring of the
network cable was
incorrect.
Check if the wiring of
network cable is
correct.
The wiring is
incorrect.
Wire it correctly.
The wiring is
correct.
Check (5).
(5) A network cable was
disconnected.
Check if the network
cable is
malfunctioning.
It has a failure.
Replace the network
cable.
It has no failure.
Check (6).
(6) Something near the
device caused it.
Check the noise,
ambient temperature,
etc. Refer to section
11.14 for the noise
reduction techniques.
It has a failure.
Take
countermeasures
against its cause.
It has no failure.
Check (7).
(7) The network module is
malfunctioning.
Replace the network
module, and then
check the
repeatability.
It is not repeatable.
Replace the network
module.
It is repeatable.
Check (8).
(8) The servo amplifier is
malfunctioning.
Replace the servo
amplifier, and then
check the
repeatability.
It is not repeatable.
Replace the servo
amplifier.
84.3 Network
module
initialization
error 2
Check it with the check method for [AL. 84.2].
Содержание MELSERVO MR-J4-B-RJ Series
Страница 7: ...2 MEMO ...
Страница 137: ...1 TROUBLESHOOTING FOR SERVO AMPLIFIER DRIVE UNIT 1 130 MEMO ...
Страница 145: ...2 TROUBLESHOOTING FOR MR CV_POWER REGENERATION CONVERTER UNIT 2 8 MEMO ...
Страница 155: ...3 TROUBLESHOOTING FOR MR CR55K 4 RESISTANCE REGENERATION CONVERTER UNIT 3 10 MEMO ...