1. TROUBLESHOOTING FOR SERVO AMPLIFIER (DRIVE UNIT)
1 - 21
Alarm No.: 13
Name: Clock error
Alarm content
A part in the servo amplifier is failure.
A clock error transmitted from the controller occurred.
[RJ010]: MR-J3-T10 came off.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
13.1 Clock error 1
(1) The MR-J3-T10 came
off during the CC-Link
IE communication.
Check if [AL. 74
Option card error 1]
occurred with alarm
history.
It is occurring.
Check it with the
check method for
[AL. 74].
[RJ010]
It did not occur.
Check (2).
(2) A part in the servo
amplifier is failure.
Disconnect the cables
except for the control
circuit power supply,
and then check the
repeatability.
It is repeatable.
Replace the servo
amplifier.
[A]
[B]
[WB]
[RJ010]
[GF]
It is not repeatable.
Check (3).
(3) A clock error
transmitted from the
controller occurred.
Check if the alarm
occurs when you
connect the amplifier
to the controller.
It occurs.
Replace the
controller.
[B]
[WB]
It does not occur.
Check (4).
(4) The servo amplifier of
the next axis is
malfunctioning.
Check if the servo
amplifier of the next
axis is malfunctioning.
It is malfunctioning. Replace the servo
amplifier of the next
axis.
It is not
malfunctioning.
Check (5).
(5) Something near the
device caused it.
Check the power
supply for noise.
Check if the connector
is shorted.
It has a failure.
Take
countermeasures
against its cause.
[A]
[B]
[WB]
[RJ010]
[GF]
13.2 Clock error 2
Check it with the check method for [AL. 13.1].
Alarm No.: 14
Name: Control process error
Alarm content
The process did not complete within the specified time.
[RJ010]: MR-J3-T10 came off.
[GF]: A part (communication IC) in the servo amplifier is failure.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
14.1 Control
process error 1
(1) The MR-J3-T10 came
off during the CC-Link
IE communication.
Check if [AL. 74
Option card error 1]
occurred with alarm
history.
It is occurring.
Check it with the
check method for
[AL. 74].
[RJ010]
It did not occur.
Check (2).
(2) The parameter setting
is incorrect.
Check if the
parameter setting is
incorrect.
It is incorrect.
Set it correctly.
[A]
[B]
[WB]
[RJ010]
[GF]
It is correct.
Check (3).
(3) Something near the
device caused it.
Check the power
supply for noise.
Check if the connector
is shorted.
It has a failure.
Take
countermeasures
against its cause.
It has no failure.
Check (4).
(4) The servo amplifier is
malfunctioning.
Replace the servo
amplifier, and then
check the
repeatability.
It is not repeatable.
Replace the servo
amplifier.
Содержание MELSERVO MR-J4-B-RJ Series
Страница 7: ...2 MEMO ...
Страница 137: ...1 TROUBLESHOOTING FOR SERVO AMPLIFIER DRIVE UNIT 1 130 MEMO ...
Страница 145: ...2 TROUBLESHOOTING FOR MR CV_POWER REGENERATION CONVERTER UNIT 2 8 MEMO ...
Страница 155: ...3 TROUBLESHOOTING FOR MR CR55K 4 RESISTANCE REGENERATION CONVERTER UNIT 3 10 MEMO ...
Страница 171: ...MEMO ...