1. TROUBLESHOOTING FOR SERVO AMPLIFIER (DRIVE UNIT)
1 - 49
Alarm No.: 37
Name: Parameter error
Alarm content
Parameter setting is incorrect.
Point table setting is incorrect.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
37.1 Parameter
setting range
error
(1) A parameter was set
out of setting range.
Check the parameter
error No. and setting
value.
It is out of setting
range.
Set it within the
range.
[A]
[B]
[WB]
[RJ010]
[GF]
It is within the
setting range.
Check (2).
(2) A parameter setting
contradicts another.
Check the parameter
error No. and setting
value.
A setting value is
incorrect.
Correct the setting
value.
A setting value is
correct.
Check (3).
(3) The parameter setting
has changed due to a
servo amplifier
malfunction.
Replace the servo
amplifier, and then
check the
repeatability.
It is not repeatable.
Replace the servo
amplifier.
37.2 Parameter
combination
error
(1) A parameter setting
contradicts another.
Check the parameter
error No. and setting
value.
A setting value is
incorrect.
Correct the setting
value. (When the
master-slave
function is set, also
check (2).)
(2) [Pr. PA01] on the
master side was set to
other than "standard
control mode" or "fully
closed loop control
mode".
Check the parameter
setting.
[Pr. PA01] is set to
other than "standard
control mode" or
"fully closed loop
control mode".
Set [Pr. PA01] to
"standard control
mode" or "fully
closed loop control
mode".
[B]
(master)
[Pr. PA01] is set to
"standard control
mode" or "fully
closed loop control
mode".
Check (4).
(3) [Pr. PA01] on the slave
side was set to other
than "standard control
mode".
Check the parameter
setting.
[Pr. PA01] is set to
other than "standard
control mode".
Set [Pr. PA01] to
"standard control
mode".
[B]
(slave)
[Pr. PA01] is set to
"standard control
mode".
Check (4).
(4)
"Forced
stop
deceleration function
selection" in [Pr. PA04]
is enabled.
Check the parameter
setting.
"Forced stop
deceleration
function selection"
setting in [Pr. PA04]
is enabled.
Disable "forced stop
deceleration
function selection"
in [Pr. PA04].
[B]
(master)
(slave)
37.3 Point
table
setting error
(1) The setting of point
tables is incorrect.
Check if the setting of
point tables is within
the setting range.
Check the parameter
error No. and point
table error No. with the
point table error No.
display on the display
of the servo amplifier.
Or check the setting
value with the point
table display of MR
Configurator2.
A setting value is
incorrect.
Correct the setting
value.
[A]
[GF]
A setting value is
correct.
Check (2).
(2) A point table setting
has changed due to a
servo amplifier
malfunction.
Replace the servo
amplifier, and then
check the
repeatability.
It is not repeatable.
Replace the servo
amplifier.
Содержание MELSERVO MR-J4-B-RJ Series
Страница 7: ...2 MEMO ...
Страница 137: ...1 TROUBLESHOOTING FOR SERVO AMPLIFIER DRIVE UNIT 1 130 MEMO ...
Страница 145: ...2 TROUBLESHOOTING FOR MR CV_POWER REGENERATION CONVERTER UNIT 2 8 MEMO ...
Страница 155: ...3 TROUBLESHOOTING FOR MR CR55K 4 RESISTANCE REGENERATION CONVERTER UNIT 3 10 MEMO ...
Страница 171: ...MEMO ...