1. TROUBLESHOOTING FOR SERVO AMPLIFIER (DRIVE UNIT)
1 - 99
Alarm No.: 96
Name: Home position setting warning
Alarm content
Home position setting could not be made.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
96.1 In-position
warning at
home
positioning
(1) INP (In-position) did not
turn on within the
specified time during
home positioning.
Check the droop
pulses during home
positioning.
It is In-position
range or more.
Adjust gains to set
droop pulses within
the In-position
range. Remove the
cause of droop
pulse occurrence,
and make home
position setting.
[A]
[B]
[WB]
[RJ010]
[GF]
96.2 Command
input warning
at home
positioning
(1) A command has already
inputted at the time of
home positioning.
Check if a command
is inputted at home
positioning.
A command is
inputted.
Set it after home
positioning.
A command is not
inputted.
Check (2).
(2) Creep speed is high.
Decrease the creep
speed, and then check
the repeatability.
It is not repeatable.
Decelerate the
creep speed, and
make home position
setting.
96.3 Servo
off
warning at
home
positioning
(1) A home positioning
was executed during
servo-off.
Check if the status is
servo-off at home
positioning.
It is servo-off.
Turn to servo-on,
and then execute the
home positioning.
[A]
96.4 Home
positioning
warning during
magnetic pole
detection
(1) Z-phase was not turned
on after servo-on.
Check if the Z-phase
was turned on.
The Z-phase was
not turned on.
Rotate the direct
drive motor to turn
on the Z-phase, and
make home position
setting.
[A]
[GF]
Alarm No.: 97
Name: Positioning specification warning
Alarm content
How to specify a positioning is incorrect for the positioning function.
Detail
No.
Detail name
Cause
Check method
Check result
Action
Target
97.1 Program
operation
disabled
warning
(1) When using the
positioning function,
start a program with the
program operation
disabled.
Check if the power of
the servo amplifier
was cycled after the
program was changed.
The power of the
servo amplifier was
not cycled.
Cycle the power of
the servo amplifier.
[A]
97.2 Next
station
position warning
(1) An abnormal value was
specified to a signal
input of the next station
position specification
and automatic operation
was started.
Check if a number of
stations per rotation
([Pr. PT28]) or more
value was not
specified to the next
station position.
The number of
stations per rotation
([Pr. PT28]) or more
value was specified.
Review the
parameter setting or
next station position
input signal.
[A]
The number of
stations per rotation
([Pr. PT28]) or more
value was not
specified.
Check (2).
(2) The power of the servo
amplifier was not cycled
after the number of
stations per rotation
([Pr. PT28]) was
changed.
Check if the power of
the servo amplifier
was cycled after the
number of stations per
rotation ([Pr. PT28])
was changed.
The power was not
cycled.
Cycle the power of
the servo amplifier.
Содержание MELSERVO MR-J4-B-RJ Series
Страница 7: ...2 MEMO ...
Страница 137: ...1 TROUBLESHOOTING FOR SERVO AMPLIFIER DRIVE UNIT 1 130 MEMO ...
Страница 145: ...2 TROUBLESHOOTING FOR MR CV_POWER REGENERATION CONVERTER UNIT 2 8 MEMO ...
Страница 155: ...3 TROUBLESHOOTING FOR MR CR55K 4 RESISTANCE REGENERATION CONVERTER UNIT 3 10 MEMO ...
Страница 171: ...MEMO ...